Angulated abutments and perimplants stress: F.E.M. analysis.
نویسندگان
چکیده
The long-term success of an implant supported prosthesis depends on many variables. In addition to the osseointegration rules that are commonly acknowledged, a clinician should consider also the biomechanical concepts related to the manufacturing process of a prosthetic structure assembly and their effects on the bone/implant interface. These concepts are particularly important when the anatomical structures leads to angulate the prosthetic component with respect to the fixture. In this study the stress distribution on the bone and on the prosthetic components was evaluated by means of a Finite Element Analysis (FEA). The effect of abutment axis angle was investigated considering three different measures: 15°, 25° and 35°. The simulation of both 450N maximal biting and 100N functional forces, highlighted the stress trend, which suggests as a maximum limit to choose an abutment with an angulation of 25°.
منابع مشابه
Three Dimensional Finite Element Analysis to Detect Stress Distribution in Spiral Implants and Surrounding Bone
BACKGROUND The aim of research was to study spiral family implant by finite element analysis (FEA) inserted in different bone qualities connected with abutments of different angulations. METHODS The biomechanical behaviour of 4.2 × 13 mm dental implants, connecting screw, straight and 15° and 25° angulated abutments subjected to static loads, in contact with high and poor bone qualities was e...
متن کاملAn In Vitro Comparison of Fracture Load of Zirconia Custom Abutments with Internal Connection and Different Angulations and Thicknesses: Part II.
PURPOSE The purpose of part II of this in vitro study was to compare the fracture load of two-piece zirconia custom abutments with different thicknesses and angulations. MATERIALS AND METHODS Forty zirconia custom abutments were divided into four groups as follows: group A1: 0.7 mm thickness and 0° angulations; group A2: 0.7 mm thickness and 15° angulations; group B1: 1 mm thickness and 0° an...
متن کاملThe effect of implant angulation and splinting on stress distribution in implant body and supporting bone: A finite element analysis
OBJECTIVE The aim of this study was to investigate the influence of implant crown splinting and the use of angulated abutment on stress distribution in implant body and surrounding bone by three-dimensional finite element analysis. MATERIALS AND METHODS For this study, three models with two implants at the site of mandibular right second premolar and first molar were designed (1): Both implan...
متن کاملAngulated Implants for Fabrication of Implant Supported Fixed Partial Denture in the Maxilla
Until recently, angled abutments have been the only solution to correcting the trajectory of the emergence profile of labially inclined implants in the maxilla. However, the clinical implications of angled abutments reveal several shortcomings. Newly designed angulated implants with a 12-degree restorative platform angulation are an alternative to angled abutments. The purpose of this article w...
متن کاملBendable vs. angulated dental implants: consideration of elastic and plastic material properties based on experimental implant material data and FEA.
AIM Bendable and angulated single-piece implants are used alternatively to screwable abutments in two-piece dental implant designs. Though used frequently, data on the stress distribution within such implants are not available and the question whether the bending contributes to fracture resistance has not been addressed. METHODS We used the method of finite element to identify von Mises stres...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- ORAL & implantology
دوره 2 1 شماره
صفحات -
تاریخ انتشار 2009