The possibilities and limitations of direct digital radiography, ultrasound and computed tomography in diagnosing pleural mesotelioma.

نویسندگان

  • Jelena Popić Ramac
  • Andrija Hebrang
  • Zlata Ivanovi-Herceg
  • Vinko Vidjak
  • Zoran Brnić
  • Karlo Novacić
  • Ivan Fistonić
چکیده

The goal of this study was to compare the possibilities and limitations of direct digital radiography of the chest (DDR), the use of ultrasound of the chest (US) and single slice computed tomography of the chest (CT) in diagnosing pleural mesothelioma. The study was conducted during the course of one year, on 80 patients who were successively referred to a specialized institution, under clinical suspicion of mesothelioma. The method of investigation was the comparison of findings, obtained by the reviewed methods of examination, with the pathohistologic results of a biopsy performed on each patient. The findings that were obtained by the enumerated methods were classified according to the radiologic signs that were found in each individual patient. We evaluated following radiological findings (signs), on each of the investigated methods: plaques, localized and generalized pleural thickenings, calcifications of the pleura, pleural effusions, parapneumonic effusions, pleural empyema, (round) atelectasis, pneumothorax, tumor mass or node, inflammatory infiltrate, elevation of the hemidiaphragm and osteolysis. The results of these were compared with pathohistologic findings and analyzed by means of standard statistical methods. The highest sensitivity was found for CT (94.4%), followed by US (92.6%), and by DDR (90.7%). The highest specificity was obtained with DDR (46.2%), followed by CT (35.5%) and US (23.8%). The comparison of these methods showed 90% diagnostic accuracy for DDR in relation to CT CT as an individual method best satisfied most of the criteria for diagnosing mesothelioma. No pathognomonic radiologic sign for mesothelioma was found.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.  Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption

Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...

متن کامل

A Comparative Study of Diagnostic Accuracy of Cone Beam Computed Tomography and Intra Oral Digital Radiography Phosphor Storage Plates in Detecting Strip Perforation in Endodontically-Treated Teeth

Background and purpose: Perforation impairs the prognosis of endodontic treatments, so, timely and accurate diagnosis is important. For this purpose, various radiographic diagnostic tools have been studied to select the method that has the least complications and helps in making the most accurate diagnosis. This study aimed to compare the accuracy of cone beam computed tomography (CBCT) and int...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Collegium antropologicum

دوره 34 4  شماره 

صفحات  -

تاریخ انتشار 2010