The Efficacy of Intraoperative Neurophysiological Monitoring Using Transcranial Electrically Stimulated Muscle-evoked Potentials (TcE-MsEPs) for Predicting Postoperative Segmental Upper Extremity Motor Paresis After Cervical Laminoplasty
نویسندگان
چکیده
STUDY DESIGN Prospective study. OBJECTIVE To investigate the efficacy of transcranial electrically stimulated muscle-evoked potentials (TcE-MsEPs) for predicting postoperative segmental upper extremity palsy following cervical laminoplasty. SUMMARY OF BACKGROUND DATA Postoperative segmental upper extremity palsy, especially in the deltoid and biceps (so-called C5 palsy), is the most common complication following cervical laminoplasty. Some papers have reported that postoperative C5 palsy cannot be predicted by TcE-MsEPs, although others have reported that it can be predicted. METHODS This study included 160 consecutive cases that underwent open-door laminoplasty, and TcE-MsEP monitoring was performed in the biceps brachii, triceps brachii, abductor digiti minimi, tibialis anterior, and abductor hallucis. A >50% decrease in the wave amplitude was defined as an alarm point. According to the monitoring alarm, interventions were performed, which include steroid administration, foraminotomies, etc. RESULTS Postoperative deltoid and biceps palsy occurred in 5 cases. Among the 155 cases without segmental upper extremity palsy, there were no monitoring alarms. Among the 5 deltoid and biceps palsy cases, 3 had significant wave amplitude decreases in the biceps during surgery, and palsy occurred when the patients awoke from anesthesia (acute type). In the other 2 cases in which the palsy occurred 2 days after the operation (delayed type), there were no significant wave decreases. In all of the cases, the palsy was completely resolved within 6 months. DISCUSSION The majority of C5 palsies have been reported to occur several days after surgery, but some of them have been reported to occur immediately after surgery. Our results demonstrated that TcE-MsEPs can predict the acute type, whereas the delayed type cannot be predicted. CONCLUSIONS A >50% wave amplitude decrease in the biceps is useful to predict acute-type segmental upper extremity palsy. Further examination about the interventions for monitoring alarm will be essential for preventing palsy.
منابع مشابه
Can intraoperative neurophysiologic monitoring during cervical spine decompression predict post-operative segmental C5 palsy?
BACKGROUND C5 nerve root palsy is a known complication after cervical laminectomy or laminoplasty, characterized by weakness of the deltoid and bicep brachii muscles. The efficacy of intraoperative monitoring of these muscles is currently unclear. In the current prospective study, intraoperative monitoring through somatosensory (SSEPs), motor (TcMEPs) evoked potentials and real-time electromyog...
متن کاملExploration of the Intraoperative Motor Evoked Potential.
STUDY DESIGN Prospective study. OBJECTIVE The objectives of the study was to (1) seek a relation between motor evoked potential (MEP) and corresponding cervical cord function in cervical compression myelopathy (CCM) and (2) explore a high-sensitive MEP range that can predict the intraoperative monitoring change ahead in cervical spine surgery. SUMMARY OF BACKGROUND DATA There have been lots...
متن کاملIntraoperative spinal cord monitoring for intramedullary surgery: an essential adjunct.
Intraoperative monitoring of the functional integrity of the spinal cord during removal of intramedullary spinal cord lesions is an aid in intraoperative decision making and a primary tool for the prediction of neurological outcome. Motor evoked potential monitoring has become the neurophysiological monitoring technique of choice for that purpose. In the senior author's experience with over 130...
متن کاملIntraoperative Monitoring of Motor-Evoked Potentials for Supratentorial Tumor Surgery
OBJECTIVE The purpose of this study was to assess the feasibility and clinical efficacy of motor evoked potential (MEP) monitoring for supratentorial tumor surgery. METHODS Between 2010 and 2012, to prevent postoperative motor deterioration, MEP recording after transcranial stimulation was performed in 84 patients with supratentorial brain tumors (45 males, 39 females; age range, 24-80 years;...
متن کاملSpecialty Section on Surgical Neuromonitoring INTRAOPERATIVE MONITORING OF SEGMENTAL SPINAL NERVE ROOT FUNCTION WITH FREE-RUN AND ELECTRICALLY-TRIGGERED ELECTROMYOGRAPHY AND SPINAL CORD FUNCTION WITH REFLEXES AND F-RESPONSES A POSITION STATEMENT BY THE AMERICAN SOCIETY OF NEUROPHYSIOLOGICAL MONITORING
Background Context. Orthodromic ascending somatosensory evoked potentials and antidromic descending neurogenic somatosensory evoked potentials monitor spinal cord sensory function. Transcranial motor stimulation monitors spinal cord motor function but only activates 4–5% of the motor units innervating a muscle. Therefore, 95–96% of the motor spinal cord systems activating the motor units are no...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 29 شماره
صفحات -
تاریخ انتشار 2016