Effect of Capacitive and Resistive Electric Transfer on Tissue Temperature, Muscle Flexibility, and Blood Circulation

نویسندگان

  • Yuki Yokota
  • Yuto Tashiro
  • Yusuke Suzuki
  • Seishiro Tasaka
  • Tomofumi Matsushita
  • Keisuke Matsubara
  • Mirei Kawagoe
  • Takuya Sonoda
  • Yasuaki Nakayama
  • Satoshi Hasegawa
  • Tomoki Aoyama
چکیده

Introduction: The differences between Capacitive and Resistive electric transfer (CRet) and hot pack (HP) in their effects on tissue temperature, muscle flexibility, and blood circulation are unknown. This study aimed to clarify the effect of CRet and HP on tissue temperature, muscle flexibility, and blood circulation. Methods: The participants were 13 healthy adults. They randomly performed three 15-minute interventions: (1) CRet, (2) HP, and (3) without powered CRet (sham). The intervention and measurement were applied to the right hamstring muscle. INDIBA® activ ProRecovery HCR902 was used in the CRet trial. The moist heat method was used in the HP trial. The measurement indexes were superficial temperature (ST), 10-mm deep temperature (DT), and 20-mm DT; the passive straight leg raise (SLR) test; and oxygenated (oxy), deoxygenated (deoxy), and total (total) hemoglobin (Hb) concentrations. Each index was measured for 30 minutes after the intervention and the amount of change (Δ) from the pre-intervention value was calculated. Results: ΔST, Δ10 mmDT, Δ20 mmDT, Δoxy-Hb, and Δtotal-Hb were significantly higher in the CRet and HP trials than in the sham trial for 30 minutes after the intervention (p<0.05). ΔSLR was significantly higher in the CRet trial than in the HP trial from 15 to 30 minutes after the intervention (p<0.01) Conclusion: Our results indicate that CRet is an efficient method for preventing and treating musculoskeletal injuries and improve muscle flexibility. In addition, it can improve blood circulation as well as HP can.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capacitive properties of body tissues.

The electric capacity of various tissues surrounding the heart has been investigated in living dogs, using frequency ranges from 10 to 10,000 c.p.s. Electrode polarization, a serious source of error in such measurements, has been corrected for. Discussion of our results and of resistivity data previously obtained in body tissues proves that the electric properties of body tissues are primarily ...

متن کامل

Comparing the Effect of Resistive Inspiratory Muscle Training and Incentive Spirometry on Respiratory Pattern of COPD patients

Background: Resistive Inspiratory Muscle Training (RIMT) is a well-known technique for rehabilitation of patients with Chronic Obstructive Pulmonary Disease (COPD). Incentive spirometry is another technique with potential viability for this application, but there is limited evidence in support of its efficacy in the rehabilitation of COPD patients. Aim: The objective of this study was to compar...

متن کامل

کاربرد PEF در بهینه‌سازی مصرف انرژی در استخراج قند از چغندر قند

The ever raising request for energy and resource limitations in the world, particularly Iran, have ever increasing attention to intense research in optimization, and economization of energy consumption. Since, the application of traditional methods for production of sugar especially in Iran is associated with high consumption of energy and water, using of pulsed electric field (PEF) technology ...

متن کامل

Numerical Study of Pure Electroconvection and Combined Electro-thermo-convection in Horizontal Channels

Electrohydrodynamic effect on natural convection in horizontal channels is investigated from a numerical point of view. The EHD effect is induced by narrow strip electrodes placed at the bottom wall of the channel. The channel is subjected in a first stage only to the electric forces, and in a second stage to the simultaneous action of a temperature gradient and an electric field. The interacti...

متن کامل

Ultrastretchable Strain Sensors Using Carbon Black-Filled Elastomer Composites and Comparison of Capacitive Versus Resistive Sensors

DOI: 10.1002/admt.201700284 system.[11] Researchers have developed highly stretchable strain sensors made of compliant elastomers and various conductive materials, such as silver nanowire,[12] carbon nanotube (CNT),[13–18] carbon grease,[19] graphene,[20] graphite,[21] laser-carbonized polyimide,[22] conductive acrylic elastomer,[10] liquid metal,[23,24] ionic liquid,[25–27] and conductive fabr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017