Comparison of the ocular response analyzer and the Goldmann applanation tonometer for measuring intraocular pressure after deep anterior lamellar keratoplasty.

نویسندگان

  • Sepehr Feizi
  • Ali Hashemloo
  • Ali Rastegarpour
چکیده

PURPOSE To compare intraocular pressure (IOP) measured using the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY) with that measured using the Goldmann applanation tonometer (GAT) in keratoconic eyes after deep anterior lamellar keratoplasty (DALK) and evaluate the influence of central graft thickness (CGT), corneal astigmatism, corneal hysteresis (CH), and corneal resistance factor (CRF) on the IOP measurements. METHODS IOP using the GAT (IOP(GAT)), CH, CRF, Goldmann-correlated IOP (IOP(g)), cornea-compensated IOP (IOP(cc)) using the ORA, and CGT were measured in 23 keratoconic eyes undergoing DALK. Bland-Altman plots were used to evaluate agreement between the tonometers. The correlation between refraction, CH, CRF, and CGT with IOP readings was investigated using multivariate regression analysis. RESULTS Mean patient age was 27.2 ± 6.5 years. Mean CGT, CH, and CRF were 547.0 ± 42.6 μm, 9.6 ± 2.1 mm Hg, and 9.4 ± 2.1 mm Hg, respectively. Mean IOP(GAT), IOP(g), and IOP(cc) were 11.3 ± 2.9, 14.1 ± 2.4, and 15.6 ± 2.6 mm Hg, respectively (P < 0.001). The 95% limit of agreement for IOP(g) and IOP(GAT) was between -2.61 and 8.19 mm Hg and for IOP(cc) and IOP(GAT) it was between -0.69 and 9.21 mm Hg. CH and CRF were significantly associated with IOP(GAT). No significant association was found between CGT and IOP readings obtained using either the ORA or GAT. CONCLUSIONS IOP readings by the ORA were significantly greater than those by the GAT, and CH and CRF play a more important role in post-DALK IOP readings by both GAT and ORA than other graft characteristics including curvature and central thickness.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular pressure measurement after penetrating keratoplasty: minified Goldmann applanation tonometer, pneumatonometer, and Tono-Pen versus manometry.

The accuracy of intraocular pressure measurement with the minified Goldmann applanation tonometer, the pneumatonometer, and the Tono-Pen tonometer were compared in post-mortem human eyes which had undergone penetrating keratoplasty. Enucleated post-mortem human eyes underwent same sized (7.75 mm) or 0.5 mm oversized (8.25 mm) autologous penetrating keratoplasty. Intraocular pressure was then se...

متن کامل

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer.

AIMS To investigate the effect of central corneal thickness and corneal curvature on intraocular pressure measurements using the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer, and to assess the agreement between the pulsatile ocular blood flow tonograph and the Goldmann applanation tonometer in intraocular pressure measurement. METHODS 479 subjects underwent int...

متن کامل

Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty

PURPOSE Post-Descemet stripping endothelial keratoplasty (DSEK) patients are prone for intraocular pressure (IOP) elevations and glaucoma. Corneal characteristics influence various IOP measuring devices in various ways. The aim of this study was to evaluate the agreement between four different IOP measuring devices: Goldmann applanation tonometer (GAT), I-care pro, Tonopen XL, and Schiotz tonom...

متن کامل

Comparison of ICare, dynamic contour tonometer, and ocular response analyzer with Goldmann applanation tonometer in glaucoma

Purpose. To compare the intraocular pressure (IOP) readings taken by ICare, Pascal dynamic contour tonometer (DCT), and ocular response analyzer (ORA) with those taken by Goldmann applanation tonometer (GAT). We sought to evaluate the influence of central corneal thickness (CCT) on IOP measurements and to compare patients’ preferences for the four tonometers. Methods. In this prospective study,...

متن کامل

Two-position measurement of intraocular pressure by PT100 noncontact tonometry in comparison with Goldmann tonometry

BACKGROUND The purpose of this study was to evaluate the precision of intraocular pressure measurements obtained by PT100 noncontact tonometry in a handheld and slit lamp-mounted position in comparison with that of Goldmann applanation tonometry in healthy young adults. METHODS Sixty eyes from 60 subjects (30 men and 30 women) aged 22 ± 1 (range 20-24) years participated in this study. Tripli...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 8  شماره 

صفحات  -

تاریخ انتشار 2011