Evaluation of a novel 2 mm internal diameter stainless steel saphenous vein to coronary artery connector: laboratory studies of on-pump and off-pump revascularization.
نویسندگان
چکیده
OBJECTIVE A second generation, 'easy-load', 2 mm internal diameter (ID), stainless steel, distal anastomotic device has been developed, and design improvements facilitate rapid connector loading with minimal magnification. The reduced size should allow application to most distal coronary vessels currently grafted. This technology may be useful in off-pump and minimally invasive surgical approaches to coronary revascularization. METHODS Two distinct models were used to evaluate the distal connector. In the first model, a single saphenous vein graft (SVG)-to-LAD procedure (n=18) was used to evaluate long-term patency of the 2 mm ID, stainless steel, distal connector in a chronic canine model. Cardiopulmonary bypass was initiated through an anterolateral thoracotomy. Aortosaphenous vein anastomoses were created using suture. In the second model, an acute off-pump feasibility study of SVG-to-LAD bypass fashioned with both proximal and distal connectors (n=15) was conducted. Aortosaphenous vein anastomoses were performed using a FDA approved vascular connector. Device loading and deployment times, graft blood flow following native LAD ligation, and device-related complications were compared. In the chronic model, the grafts were examined by angiography and gross and microscopic examination at animal sacrifice. RESULTS All 33 animals survived the procedures. All grafts were widely patent after a minimum 30 (n=8), 90 (n=5), and 180 days (n=5) in the chronic model. Distal graft loading and deployment times, graft blood flow rates, and device-related complications were similar in both procedures. In the off-pump feasibility study, total grafting time including loading and deployment was 10:54+/-2:54 min. CONCLUSIONS Sutureless SVG-to-coronary artery bypass is feasible, rapid, and reproducible with on- and off-pump surgical techniques using a 2 mm ID, stainless steel, distal connector. In this model, early graft patency was 100% with either procedure, and grafts performed on-pump were widely patent at 30, 90, and 180 days. Few device-related complications occurred, each easily managed without compromising graft integrity, and the incidence of events was similar whether on- or off-pump techniques were employed. This or similar technologies may become an important addition to the management of coronary artery disease, particularly in off-pump or minimally invasive approaches.
منابع مشابه
Major Leg Wound Complications After Saphenous Vein Harvest for Coronary Revascularization
Background: Major leg wound complications after coronary artery bypass graft procedures are infrequent and few are reported in the litrature.We present our experience in treating 30 patients with major leg wound complications after coronary revascularization procedures. Materials and Methods: A retrospective review of 2100 bypass procedures with saphenous veingraft performed over a 5-years p...
متن کاملCardiovascular Surgery Off-Pump Coronary Artery Bypass Surgery Is Associated With Worse Arterial and Saphenous Vein Graft Patency and Less Effective Revascularization
Background—The Department of Veterans Affairs Randomized On/Off Bypass (ROOBY) trial compared clinical and angiographic outcomes in off-pump versus on-pump coronary artery bypass graft (CABG) surgery to ascertain the relative efficacy of the 2 techniques. Methods and Results—From February 2002 to May 2007, the ROOBY trial randomized 2203 patients to off-pump versus on-pump CABG. Follow-up angio...
متن کاملOff-Pump Coronary Artery Bypass Surgery Is Associated With Worse Arterial and Saphenous Vein Graft Patency and Less Effective Revascularization
Background—The Department of Veterans Affairs Randomized On/Off Bypass (ROOBY) trial compared clinical and angiographic outcomes in off-pump versus on-pump coronary artery bypass graft (CABG) surgery to ascertain the relative efficacy of the 2 techniques. Methods and Results—From February 2002 to May 2007, the ROOBY trial randomized 2203 patients to off-pump versus on-pump CABG. Follow-up angio...
متن کاملجراحی بای پس عروق کرونر بدون استفاده از ماشین قلب- ریه: روشی مطمئن برای ریواسکولاریزیشن کامل
In recent years off-pump coronary artery bypass surgery (OPCAB) has emerged as preferred method for revascularization of coronary arteries in relatively selected group of patients. Considering patients receiving incomplete revascularization need significantly higher postoperative catheterization and re-intervention (PTCA or CABG), we performed this study to identify safety and feasibility of th...
متن کاملPredictors and prevention of flow insufficiency due to limited flow demand
BACKGROUND We investigated the impacts of flow demand and native coronary stenosis on graft flow and patency. METHODS We reviewed the angiograms of 549 bypass grafts in 301 patients who underwent off-pump coronary artery bypass grafting since 2007. Grafts consisted of 237 internal thoracic artery to left anterior descending artery; 97 internal thoracic artery and 52 saphenous vein grafts to l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 23 6 شماره
صفحات -