Immunoturbidimetry of albumin and immunoglobulin G in urine.
نویسنده
چکیده
I describe a rapid, sensitive immunoturbidimetric assay for measuring urinary albumin and immunoglobulin G with use of an automated spectrophotometer. Diluted urine samples and polyethylene glycol in phosphate-buffered saline are pipetted into the cuvettes of the spectrophotometer. The initial absorbances of the samples are measured at 340 nm; antiserum to albumin or to immunoglobulin G is added to each tube, and after 2 min at 37 degrees C the absorbance of the mixtures is read at 340 nm. The initial blank absorbances of the samples are subtracted from the final absorbances automatically. The change in absorbance is linear with concentration in the range of 5-400 mg/L for albumin and 3-1000 mg/L for IgG. The lower limit of the determination is 5 mg/L for albumin, 3 mg/L for IgG. Linear correlations were observed between the concentrations of albumin and immunoglobulin G determined by this method (x) and those determined by radial immunodiffusion (y). The regression equation for albumin was y = 0.84x + 0.03 (r = 0.99, n = 87), and for IgG y = 0.94x + 0.02 (r = 0.98, n = 87).
منابع مشابه
Comparison between immunoturbidimetry, size-exclusion chromatography, and LC-MS to quantify urinary albumin.
BACKGROUND The accurate and precise measurement of urinary albumin is critical, since even minor increases are diagnostically sensitive indicators of renal disease, cardiovascular events, and risk for death. To gain insights into potential measurement biases, we systematically compared urine albumin measurements performed by LC-MS, a clinically available immunoturbidimetric assay, and size-excl...
متن کاملUrinary Total Protein as the Predictor of Albuminuria in Diabetic Patients
BACKGROUND In order to detect nephropathy, measurement of total (24 hrs) urinary albumin or albumin/creatinin ratio in random urine samples is being recommended. But methods of albumin measurement are not available in all laboratories and also cost about 6 times more than that of urinary total protein measurement. OBJECTIVES This Study was performed to determine appropriate cut off point in 2...
متن کاملEvaluation of tests for microalbuminuria screening in patients with diabetes.
BACKGROUND The first step in the diagnosis of diabetic nephropathy is to measure albumin in a spot urine sample. The aim of this study was to assess the accuracy of urinary albumin concentration (UAC), urinary albumin-to-creatinine ratio (UACR), and the Micral-Test II in a random urine specimen (RUS) for microalbuminuria screening in diabetes mellitus. METHODS Two hundred and seventy-eight pa...
متن کاملRapid microalbuminuria screening in type 2 diabetes mellitus: simplified approach with Micral test strips and specific gravity.
BACKGROUND Microalbuminuria is known to be a harbinger of serious complications in type 2 diabetes mellitus. Since medical intervention at the onset of microalbuminuria can be critical in reducing these adverse outcomes, it is widely agreed that type 2 diabetic patients should be screened for microalbuminuria. The purpose of the present study is to evaluate Micral test strips in conjunction wit...
متن کاملReproducibility of albuminuria in type 2 diabetic subjects. Findings from the Renal Insufficiency And Cardiovascular Events (RIACE) study.
BACKGROUND Measurement of urinary albumin excretion (UAE) shows important intra-individual variability suggesting the need for multiple assessments. This study aimed at investigating the reproducibility of UAE in type 2 diabetes. METHODS UAE was obtained from two to three samples collected in a 3- to 6-month period from 4062 of the 15 773 type 2 diabetic subjects participating in the Renal In...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 28 6 شماره
صفحات -
تاریخ انتشار 1982