Hydrogen peroxide biosensor based on hemoglobin modified zirconia nanoparticles-grafted collagen matrix.

نویسندگان

  • Shuizhen Zong
  • Yong Cao
  • Yuming Zhou
  • Huangxian Ju
چکیده

A novel method for the immobilization of hemoglobin (Hb) and preparation of reagentless biosensor was proposed using a biocompatible non-toxic zirconia enhanced grafted collagen tri-helix scaffold. The formed membrane was characterized with UV-vis and FT-IR spectroscopy, scanning electron microscope and electrochemical methods. The Hb immobilized in the matrix showed excellent direct electrochemistry with an electron transfer rate constant of 6.46 s(-1) and electrocatalytic activity to the reduction of hydrogen peroxide. The apparent Michaelis-Menten constant for H(2)O(2) was 0.026 mM, showing good affinity. Based on the direct electrochemistry, a new biosensor for H(2)O(2) ranging from 0.8 to 132 microM was constructed. Owing to the porous structure and high enzyme loading of the matrix the biosensor exhibited low limit of detection of 0.12 microM at 3sigma, fast response less than 5 s and high sensitivity of 45.6 mA M(-1) cm(-2). The biosensor exhibited acceptable stability and reproducibility. ZrO(2)-grafted collagen provided a good matrix for protein immobilization and biosensing preparation. This method was useful for monitoring H(2)O(2) in practical samples with the satisfactory results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Zirconia nanoparticles enhanced grafted collagen tri-helix scaffold for unmediated biosensing of hydrogen peroxide.

A novel, biocompatible, thermally steady, and nontoxic zirconia enhanced grafted collagen tri-helix scaffold was prepared on a graphite electrode. This scaffold provided a microenvironment for loading biomolecules and helped to retain their natural structure. UV-vis spectroscopy and scanning electron microscopy were used to characterize the scaffold and the structure of immobilized biomolecules...

متن کامل

Mediatorless Impedance Studies with Titanium Dioxide Conjugated Gold Nanoparticles for Hydrogen Peroxide Detection

An impedimetric-based biosensor constructed using gold nanoparticles (AuNP) entrapped within titanium dioxide (TiO₂) particles for hydrogen peroxide (H₂O₂) detection is the main feature of this research. The matrix of the biosensor employed the surface of TiO₂, which was previously modified with an amine terminal group using 3-Aminopropyltriethoxysilane (APTS) at a low temperature to create a r...

متن کامل

Highly sensitive and selective uric acid biosensor based on direct electron transfer of hemoglobin-encapsulated chitosan-modified glassy carbon electrode.

A uric acid biosensor based on the direct electron transfer of a hemoglobin-encapsulated chitosan-modified glassy carbon electrode was developed for a highly sensitive and selective analysis in urine samples. The modified electrode was prepared by the encapsulation of hemoglobin and uricase in a chitosan matrix. The hydrogen peroxide produced from the catalytic oxidation of uric acid by uricase...

متن کامل

Amperometric Hydrogen Peroxide Biosensor Based on Immobilization of Hemoglobin on a Glassy Carbon Electrode Modified with Fe3O4/Chitosan Core-Shell Microspheres

Novel magnetic Fe(3)O(4)/chitosan (CS) microspheres were prepared using magnetic Fe(3)O(4) nanoparticles and the natural macromolecule chitosan. Then, using an easy and effective hemoglobin (Hb) immobilization method, an innovative biosensor with a Fe(3)O(4)/CS-Hb-Fe(3)O(4)/CS "sandwich" configuration was constructed. This biosensor had a fast (less than 10 s) response to H(2)O(2) and excellent...

متن کامل

A novel amperometric hydrogen peroxide biosensor based on electrospun Hb-collagen composite.

In this paper, the hemoglobin (Hb)-collagen microbelt modified electrode with three-dimensional configuration was fabricated via the electrospinning method. Direct electron transfer of the Hb immobilized into the electrospun collagen microbelts was greatly facilitated. The apparent heterogeneous electron transfer rate constant (k(s)) was calculated to be 270.6s⁻¹. The electrospun Hb-collagen mi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytica chimica acta

دوره 582 2  شماره 

صفحات  -

تاریخ انتشار 2007