چکیده

Multi-analyte detection of environmentally relevant pesticides is performed by using a two-channelled surface plasmon resonance (SPR) biosensor. The special design of the SPR instrument allows the determination of several analytes (DDT, chlorpyrifos and carbaryl) via different immobilization formats. First, simultaneous pesticide monitoring is possible by flowing chlorpyrifos, carbaryl or DDT samples separately over each channel of the SPR system, wherein their corresponding recognition element was previously immobilized. The second approach is based on the multiple and combined immobilization of several analyte recognition elements on the sensing surface of one individual flow cell. In this format, the analysis time for all three pesticides varied from 40 to 60 min depending on the number of regeneration cycles. In most cases, similar detection limits were attained for the target analyte irrespective of the assay format, with sensitivity values at the nanogram per litre level (18-50 ng L(-1)). The assay reproducibility was proved through the repeated use of the same sensor surface for over more than 200 assay cycles, whereas the absence of biosensor response to non-related analytes showed the specificity and reliability of the analysis. The SPR instrument, including optics, electronics and microfluidics, is already commercialised by the company SENSIA, SL.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-analyte surface plasmon resonance biosensing.

Surface plasmon resonance (SPR) biosensors are affinity sensing devices exploiting a special mode of electromagnetic field-surface plasmon-polariton-to detect the binding of analyte molecules from a liquid sample to biomolecular recognition elements immobilized on the surface of the sensor. In this paper, we review advances of SPR biosensor technology towards detection systems for the simultane...

متن کامل

High-frequency phase shift measurement greatly enhances the sensitivity of QCM immunosensors.

In spite of being widely used for in liquid biosensing applications, sensitivity improvement of conventional (5-20MHz) quartz crystal microbalance (QCM) sensors remains an unsolved challenging task. With the help of a new electronic characterization approach based on phase change measurements at a constant fixed frequency, a highly sensitive and versatile high fundamental frequency (HFF) QCM im...

متن کامل

Development of an aptamer beacon for detection of interferon-gamma.

Traditional antibody-based affinity sensing strategies employ multiple reagents and washing steps and are unsuitable for real-time detection of analyte binding. Aptamers, on the other hand, may be designed to monitor binding events directly, in real-time, without the need for secondary labels. The goal of the present study was to design an aptamer beacon for fluorescence resonance energy transf...

متن کامل

Surface Plasmon Resonance Imaging Sensors: A Review

Surface plasmon resonance (SPR) imaging sensors realize label free, real-time, highly sensitive, quantitative, high throughput biological interaction monitoring and the binding profiles from multi-analytes further provide the binding kinetic parameters between different bio-molecules. In the past two decades, SPR imaging sensors found rapid increasing applications in fundamental biological stud...

متن کامل

Investigating a Functionalized Terthiophene Surface for the Detection of Progesterone Using Surface Plasmon Resonance

Herein we report a rapid and sensitive surface Plasmon resonance (SPR) biosensor to detect progesterone (P4), a model analyte of small molecules. A terthiophene scaffold with an oligoethylene glycol (OEG) linker is used as an anchor for the P4-ovalbumin (OVA) immobilization on gold to form a stable, regenerable SPR surface. Subsequently, inhibition SPR immunoassays based on this terthiophene/OV...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical and bioanalytical chemistry

دوره 387 4  شماره 

صفحات  -

تاریخ انتشار 2007