Can Pin-on-Disk Testing Be Used to Assess the Wear Performance of Retrieved UHMWPE Components for Total Joint Arthroplasty?

نویسندگان

  • Steven M Kurtz
  • Daniel W MacDonald
  • Sevi Kocagöz
  • Mariya Tohfafarosh
  • Doruk Baykal
چکیده

The objective of this study was to assess the suitability of using multidirectional pin-on-disk (POD) testing to characterize wear behavior of retrieved ultrahigh molecular weight polyethylene (UHMWPE). The POD wear behavior of 25 UHMWPE components, retrieved after 10 years in vivo, was compared with 25 that were shelf aged for 10-15 years in their original packaging. Components were gamma sterilized (25-40 kGy) in an air or reduced oxygen (inert) package. 9 mm diameter pins were fabricated from each component and evaluated against CoCr disks using a super-CTPOD with 100 stations under physiologically relevant, multidirectional loading conditions. Bovine serum (20 g/L protein concentration) was used as lubricant. Volumetric wear rates were found to vary based on the aging environment, as well as sterilization environment. Volumetric wear rates were the lowest for the pins in the gamma inert, shelf aged cohort. These results support the utility of using modern, multidirectional POD testing with a physiologic lubricant as a novel method for evaluating wear properties of retrieved UHMWPE components. The data also supported the hypothesis that wear rates of gamma-inert liners were lower than gamma-air liners for both retrieved and shelf aging conditions. However, this difference was not statistically significant for the retrieved condition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear of retrieved UHMWPE hip liners.

After the gamma-irradiation sterilization, the most widely used orthopaedic grade polymer bearing liner material for the total joint replacement, ultra-high molecular weight polyethylene (UHMWPE), degrades through the progressive in vivo oxidation. The oxidative degradation makes UHMWPE brittle and leads to reduction of its mechanical properties. In this study, the effect of the in vivo post-ir...

متن کامل

High frequency circular translation pin-on-disk method for accelerated wear testing of ultrahigh molecular weight polyethylene as a bearing material in total hip arthroplasty.

The temporal change of the direction of sliding relative to the ultrahigh molecular weight polyethylene (UHMWPE) component of prosthetic joints is known to be of crucial importance with respect to wear. One complete revolution of the resultant friction vector is commonly called a wear cycle. It was hypothesized that in order to accelerate the wear test, the cycle frequency may be substantially ...

متن کامل

Storing Period Effects on Wear Properties in Uhmwpe Inserts for Artificial Joints

INTRODUCTION Artificial joints have been increasingly used in treatment of physically disabled people who have severely damaged joints. In artificial joint, ultra high molecular weight polyethylene (UHMWPE) has been usually employed as a buffer because of its very low friction coefficient, high wear resistance, high impact strength, and biocompatibility. [1]. When artificial joints were replace...

متن کامل

Using a surrogate contact pair to evaluate polyethylene wear in prosthetic knee joints.

With recent improvements to the properties of ultra-high molecular weight polyethylene (UHMWPE) used in joint replacements, prosthetic knee and hip longevity may extend beyond two decades. However, it is difficult and costly to replicate such a long in vivo lifetime using clinically relevant in vitro wear testing approaches such as walking gait joint simulators. We advance a wear test intermedi...

متن کامل

In vitro wear simulation on the RandomPOD wear testing system as a screening method for bearing materials intended for total knee arthroplasty.

The 16-station RandomPOD wear test system, previously validated for prosthetic hip wear, was used in the simulation of knee wear mechanisms with a ball-on-flat test configuration. This consisted of a CoCr pin with a ground and polished spherical bearing surface (radius 28 mm) against a conventional, gamma-sterilized UHMWPE disk in serum lubrication. The biaxial motion, consisting of x and y tra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014