A home monitoring system for nasal CPAP.
نویسندگان
چکیده
A compact portable sensing system (PSS) was developed for home monitoring of patients with obstructive sleep apnea treated with nasal continuous positive-airway pressure (CPAP). The system consisted of a solid-state pressure sensor connected with plastic tubing to the side port of the nasal CPAP mask, a power supply, and a strip chart recorder. The device was validated against standard polysomnography in ten patients with obstructive sleep apnea undergoing overnight nasal CPAP trials. A total of 397 apneas and hypopneas were observed in the ten patients. The PSS device detected 386 events (sensitivity, 97.2 percent). In addition, there were 29 false positive events noted by the device (positive predictive value, 93 percent). The device was then tested at home in 23 patients on nasal CPAP. Eight of these patients had persistent apneas requiring adjustment of their CPAP pressure. The PSS device allowed for accurate reevaluation of nasal CPAP settings in the patient's home without necessitating expensive, time-consuming in-hospital laboratory polysomnographic studies.
منابع مشابه
Unattended home diagnosis and treatment of obstructive sleep apnea without polysomnography.
OBJECTIVE To test the effectiveness of unattended home monitoring along with automatic titrating continuous positive airway pressure (auto-CPAP) as an acceptable method for diagnosing and prescribing proper CPAP pressure for treatment of patients presenting with classic symptoms of obstructive sleep apnea (OSA). DESIGN Nonrandomized, prospective case study of 63 patients with a presumptive di...
متن کاملدرمان زودرس با Nasal CPAP در نوزادان نارس با سندرم دیسترس تنفسی
Background: Respiratory distress syndrome (RDS) is a major cause of mortality among premature neonates. The present study was conducted to find out whether early nasal CPAP therapy could eliminate the need for mechanical ventilation in premature neonates with RDS. Materials and methods: For this clinical trial, premature neonates with RDS during the first 6 hours following the delivery were as...
متن کاملLong-term compliance with nasal continuous positive airway pressure therapy of obstructive sleep apnea.
In an attempt to identify predictors of long-term compliance with nasal continuous positive airway pressure (CPAP), we reviewed the records of 125 patients with obstructive sleep apnea (OSA) referred to our center for nasal CPAP trials. Severity of sleep apnea, sleep staging, daytime hypersomnolence, effectiveness of nasal CPAP, previous palatal surgery, and adverse reactions were compared in c...
متن کاملA comparison of CPAP and CPAPFLEX in the treatment of obstructive sleep apnea in World Trade Center responders: study protocol for a randomized controlled trial
BACKGROUND Following the World Trade Center disaster, a large number of individuals involved in rescue and recovery activity were exposed to significant amounts of dust, and reported symptoms of chronic nasal and sinus inflammation. An unusually high prevalence of obstructive sleep apnea (OSA) has also been observed in this World Trade Center Responder population. This project aims to examine t...
متن کاملThe Effect of Body Position on Pain Due to Nasal Continuous Positive Airway Pressure (CPAP) in Premature Neonates: A Cross-Over Clinical Trial Study
Background The most common cause of admission to neonatal intensive care units (NICU) is respiratory distress syndrome. One of the respiratory assistance methods is using nasal continuous positive airway pressure (CPAP). Regarding the importance of pain control which is one of the major priorities in neonatal nursing care, this study aimed to evaluate the effect of body position on pain due to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 93 4 شماره
صفحات -