Dual Monitoring with Stump Pressure and Electroencephalography During Carotid Endarterectomy
نویسندگان
چکیده
BACKGROUND Intraoperative monitoring during carotid endarterectomy is crucial for cerebral protection. We investigated the results of carotid endarterectomy under dual monitoring with stump pressure and electroencephalography. METHODS We retrospectively reviewed the medical records of 50 patients who underwent carotid endarterectomy between March 2010 and February 2016. We inserted a temporary shunt if the stump pressure was lower than 35 mm Hg or if any intraoperative change was observed on electroencephalography. RESULTS Seventeen (34%) patients used a temporary shunt, and the mean stump pressure was 26.8 mm Hg in the shunt group and 46.5 mm Hg in the non-shunt group. No postoperative mortality or bleeding occurred. Postoperatively, there were 3 cases (6%) of minor stroke, all of which took place in the shunt group. A comparison of the preoperative and the intraoperative characteristics of the shunt group with those of the non-shunt group revealed no statistically significant difference between the 2 groups (p <0.01). CONCLUSION Dual monitoring with stump pressure and electroencephalography was found to be a safe and reliable monitoring method with results comparable to those obtained using single monitoring. Further study should be performed to investigate the precise role of each monitoring method.
منابع مشابه
Monitoring cerebral ischemia during carotid endarterectomy and stenting
Current therapy for carotid stenosis mainly includes carotid endarterectomy and endovascular stenting, which may incur procedure-related cerebral ischemia. Several methods have been employed for monitoring cerebral ischemia during surgery, such as awake neurocognitive assessment, electroencephalography, evoked potentials, transcranial Doppler, carotid stump pressure, and near infrared spectrosc...
متن کاملCerebral monitoring during carotid endarterectomy--a comparison between electroencephalography, transcranial cerebral oximetry and carotid stump pressure.
OBJECTIVE Various modalities are used for cerebral monitoring during carotid endarterectomy (CEA). The aim of this study was to evaluate whether transcranial cerebral oximetry (TCO) and carotid stump pressure (SP) are as accurate as electroencephalography (EEG) for monitoring cerebral ischaemia during carotid cross-clamping. METHODS One hundred consecutive patients who underwent CEA were stud...
متن کاملRelation between middle cerebral artery blood flow velocity and stump pressure during carotid endarterectomy.
BACKGROUND AND PURPOSE Many patient monitoring techniques have been used for detecting cerebral hypoperfusion during carotid endarterectomy. We compared middle cerebral artery blood flow velocities with carotid artery stump pressures to evaluate the indications for common carotid artery cross-clamp shunting and the probable hemodynamic causes of cerebrovascular complications. METHODS Blood fl...
متن کاملCEREBRAL BLOOD FLOW FOLLOWING UNILATERAL CAROTID ARTERY OCCLUSION: An Experimental Study
In this study, 26 white New Zealand rabbits weighing between 2-3.5kg were used. Anaesthesia was induced with 1.5glkg urethane intraperitoneally. The ear vein was canulated and an intravenous supply was provided. The femoral artery was catheterized and used to monitor blood pressure. The haemodynamic effects of carotid artery occlusion are not well known. Therefore occluded carotid artery causes...
متن کاملLateralisation of the BIS Sensor during Carotid Endarterectomy Does it Really Matter?
Bispectral index (BIS) monitoring is commonly used to provide a measure of depth during general anaesthesia in attempt to reduce the rare occurrence of awareness [1,2]. The Bispectral Index is a generated number between 0 and 100 that is derived through utilization of a number of advanced EEG signal processing techniques including bispectral analysis, power spectral analysis, and time domain an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 50 شماره
صفحات -