[Evaluation of the pelvi-ureteral function through a new urine bolusmetry. II. Simultaneous measurement of urine bolus volume and electroureterogram].

نویسنده

  • T Harada
چکیده

New equipment to evaluate the urine transport function of the ureteropelvic system has been developed. Simultaneous measurement of urine bolus volume and electrical activity in the ureter is possible by means of this equipment. A urine bolus volume measuring system, which is based on the heat electrical method, is located in the probe tip, and bipolar electrodes for EMG are located in the stem of the Fr. 4 ureteral catheter. Two kinds of experiments were performed. One was an examination of the new probe through a pervioureteric model using an infusion pump and Nelatons' catheters of various diameters. The other was an animal experiment. The changes in ureteral peristalsis and urine bolus volume in response to diuretics were examined in mongrel dogs through application of this equipment. The following results were obtained: There was a logarithmic relation between perfusion flow rate in catheters used as ureteral models and the values of voltage depression measured by the heat electrical method. The urine bolus volume was calculated closely through a formula which had been developed from the model experiments. In animal experiments, the bolus volume increased significantly and a transient increase in peristalsis was noted after the administration of diuretics although there was no significant change in peristaltic velocity. Some pelvioureteric function parameters, i.e. peristaltic frequency, peristaltic velocity, urine bolus volume, volume, bolus length and ureteral width, are feasible calculations. These results indicate that bolusmetry by using this new probe is a valuable method for evaluation of urine transport function in the pelvioureteric system, and suitable for clinical use as well as animal experiments.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The estimation of urine bolus volume for patients with congenital hydronephrosis.

A new examination (bolusmetry) to evaluate the urine transport function of the ureteropelvic system was performed in 7 adult patients with congenital unilateral hydronephrosis. Whistle-tipped Fr. 5 catheters were introduced to each ureter about 5 cm proximal from the ureteral orifice by transurethral endoscopic technique. Bolus volume and frequency, and changes in them caused by furosemide inje...

متن کامل

Characterization of alpha-adrenoceptor subtypes involved in regulation of ureteral fluid transport.

Experiments were carried out in the dog by the use of experimental procedure which permits to assess independently changes in uretheral peristaltic frequency, bolus volume and intraluminal pressure and flow volume in order to characterize alpha-adrenoceptor subtypes involved in regulation of ureteral urine transport. Norepinephrine caused an increase in ureteral peristaltic frequency, an elevat...

متن کامل

Combination Therapy with Losartan and α-Tocopherol in Acute Ureteral Obstruction-Induced Renal Excretory Dysfunction and Acidification Defect

Background: Previous study by the authors showed that a-tocopherol prevents oxidative stress but would not improve depressed excretory variables in post-obstructed kidney (POK) after release of 24-h unilateral ureteral obstruction (UUO). This study is a supplementary investigation on the effects of a-tocopherol combined with an antagonist of angiotensin-II type-1 (AT1) receptor on renal dysfunc...

متن کامل

Simultaneous Determination of Ibuprofen and Caffeine in Urine Samples by Combining MCR-ALS and Excitation-emission Data

Second order advantage of excitation-emission fluorescence matrix was applied for the simultaneous determination of ibuprofen and caffeine. The proposed method is based on the measurement of the native fluorescence and recording emission spectra of ibuprofen and caffeine in different excitation wavelengths. The mixture of these compounds was resolved by multivariate curve resolution coupled wit...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nihon Heikatsukin Gakkai zasshi

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 1983