Point-of-Care Hemoglobin A1c Testing: An Evidence-Based Analysis.

ثبت نشده
چکیده

BACKGROUND The increasing prevalence of diabetes in Ontario means that there will be growing demand for hemoglobin A1c (HbA1c) testing to monitor glycemic control for the management of this chronic disease. Testing HbA1c where patients receive their diabetes care may improve system efficiency if the results from point-of-care HbA1c testing are comparable to those from laboratory HbA1c measurements. OBJECTIVES To review the correlation between point-of-care HbA1c testing and laboratory HbA1c measurement in patients with diabetes in clinical settings. DATA SOURCES The literature search included studies published between January 2003 and June 2013. Search terms included glycohemoglobin, hemoglobin A1c, point of care, and diabetes. REVIEW METHODS Studies were included if participants had diabetes; if they compared point-of-care HbA1c devices (licensed by Health Canada and available in Canada) with laboratory HbA1c measurement (reference method); if they performed point-of-care HbA1c testing using capillary blood samples (finger pricks) and laboratory HbA1c measurement using venous blood samples within 7 days; and if they reported a correlation coefficient between point-of-care HbA1c and laboratory HbA1c results. RESULTS Three point-of-care HbA1c devices were reviewed in this analysis: Bayer's A1cNow+, Bio-Rad's In2it, and Siemens' DCA Vantage. Five observational studies met the inclusion criteria. The pooled results showed a positive correlation between point-of-care HbA1c testing and laboratory HbA1c measurement (correlation coefficient, 0.967; 95% confidence interval, 0.960-0.973). LIMITATIONS Outcomes were limited to the correlation coefficient, as this was a commonly reported measure of analytical performance in the literature. Results should be interpreted with caution due to risk of bias related to selection of participants, reference standards, and the multiple steps involved in POC HbA1c testing. CONCLUSIONS Moderate quality evidence showed a positive correlation between point-of-care HbA1c testing and laboratory HbA1c measurement. Five observational studies compared 3 point-of-care HbA1c devices with laboratory HbA1c assays, and all reported strong correlation between the 2 tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of costs of hemoglobin A1c determination by point-of-care testing (POCT) and standard hemoglobin A1c analyzer

OBJECTIVE The use of the levels of hemoglobin A1c for the monitoring of glycemic control in patients with diabetes mellitus (DM) is an accepted method of clinical usefulness. A study was performed to assess the relative costs of hemoglobin A1c determination by diagnostic testing at or near the site of patient care (point-of-care testing, POCT) and using the standard hemoglobin A1c analyzer. MET...

متن کامل

Glycated hemoglobin assessment in clinical practice: comparison of the A1cNow point-of-care device with central laboratory testing (GOAL A1C Study).

BACKGROUND The Glycemic Optimization with Algorithms and Labs At Po1nt of Care (GOAL A1C) Study assessed the effect of titration monitoring strategies and methods of A1C testing on glycemic control in patients with type 2 diabetes failing oral therapy and beginning basal insulin glargine. The availability of both point-of-care (POC) and central laboratory A1C values provided an opportunity to e...

متن کامل

Analysis of office-based glycohemoglobin measurement.

Hemoglobin A1c (HbA1c) measurements are important for monitoring glycemic control in patients with diabetes. The positive impact of point-of-care HbA1c measurements on patient management is described in the literature. The general analytical requirements for HbA1c testing are described. The analytical evaluation of a new point-of-care HbA1c analyzer, suitable for a physician's office, against t...

متن کامل

Impact of active versus usual algorithmic titration of basal insulin and point-of-care versus laboratory measurement of HbA1c on glycemic control in patients with type 2 diabetes: the Glycemic Optimization with Algorithms and Labs at Point of Care (GOAL A1C) trial.

OBJECTIVE The objective of this study was to assess the impact of active versus usual monitoring of algorithmic insulin titration and point-of-care (POC) versus laboratory HbA1c (A1C) measurement on glycemic control in primary care. RESEARCH DESIGN AND METHODS The Glycemic Optimization with Algorithms and Labs at Point of Care (GOAL A1C) study was a 24-week, randomized, parallel-group, four-a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ontario health technology assessment series

دوره 14 8  شماره 

صفحات  -

تاریخ انتشار 2014