Performance evaluation of duct-mounted relative humidity sensors used in building HVAC applications

نویسندگان

  • Shailesh Narayan Joshi
  • Greg Maxwell
  • Steve Hoff
  • Eugene Takle
  • Maria Corsi
چکیده

Relative humidity sensors are common components in building heating, ventilating, and air-conditioning (HVAC) systems, and their performance can significantly impact energy use in these systems. A study was undertaken to test and evaluate the most commonly used relative humidity sensors in building HVAC systems, namely the capacitive and resistive types. Sensor models from six different manufacturers were used for testing. Three sensors of each model for a total of 18 sensors were tested, nine of them were capacitive-type sensors and nine were resistive-type sensors. The performance of these sensors was determined by subjecting the sensors to a series of tests that included accuracy, linearity, repeatability, hysteresis, ageing, response time and stress. For each test, a detailed method of test was developed and peer reviewed. The accuracy test results showed that two of the six humidity sensor models were within manufacturer specified accuracy, while a third sensor model did not met the manufactured specified accuracy at any humidity level tested, and finally, the remaining three sensor models, met the manufacturer specified accuracy for only part of the humidity range. Further, the repeatability of all sensors models at 50% RH and 15, 25, and 35°C was within 1.5% RH. The maximum hysteresis for all sensors was less than 3.2% for all humidities and temperatures. And finally, at 25°C, Model-B sensor had the largest nonlinearity of -3.8% while Model-C sensor had the least nonlinearity of 0.0%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی کارایی سیستم تهویه مطبوع یک ساختمان اداری در شهر تهران

Introduction: One of the factors influencing on indoor air quality of the buildings is performance of HVAC (heating, ventilation, and air conditioning) systems. These systems supply clean and odorless air, with temperature, humidity, and air velocity within comfort ranges for the residents. The aim of this study was to evaluate performance HVAC system in an administrative building in Tehran. .M...

متن کامل

The Transient Response of Capacitive Thin-Film Polymer Humidity Sensors

The transient response of capacitive thin-jïlm polymer humidity sensors to step changes in humidity and temperature as a function of air velocity was investigated. Two duct-mounted humidity sensors (designated Candidate X and Candidate Y) from two manufacturers, each with thin-film capacitive humidity sensing elements and temperature output, were used in the study. The transient performance of ...

متن کامل

Building Environment Analysis based on Temperature and Humidity for Smart Energy Systems

In this paper, we propose a new HVAC (heating, ventilation, and air conditioning) control strategy as part of the smart energy system that can balance occupant comfort against building energy consumption using ubiquitous sensing and machine learning technology. We have developed ZigBee-based wireless sensor nodes and collected realistic temperature and humidity data during one month from a labo...

متن کامل

Optimized Selection and Placement of Sensors using Building Information Models (BIM)

The performance of an advanced lighting system is heavily influenced by the placement and orientation of occupancy sensors and photo-sensors. Incorrect sensor placement can compromise system performance, cause discomfort to occupants and diminish savings. The current process of manually selecting sensors and placing them on a floor plan in a design tool is not only suboptimal but also is tediou...

متن کامل

The Empirical Assessment of Vibration in HVAC Systems

Background and purpose: Vibration caused by ventilation systems in buildings is one of the harmful physical factors that can cause harm to residents. Therefore, measuring and controlling vibration is important. Materials and Methods:  In the first step of the study, the vibration accelerometer was placed on the base of a fan where the vibrations were sent toward the duct wall. A vibration asse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015