High temperature heat source generation with quasi-continuous wave semiconductor lasers at power levels of 6 W for medical use.

نویسندگان

  • Takahiro Fujimoto
  • Yusuke Imai
  • Kazuyoku Tei
  • Shinobu Ito
  • Hideko Kanazawa
  • Shigeru Yamaguchi
چکیده

We investigate a technology to create a high temperature heat source on the tip surface of the glass fiber proposed for medical surgery applications. Using 4 to 6 W power level semiconductor lasers at a wavelength of 980 nm, a laser coupled fiber tip was preprocessed to contain a certain amount of titanium oxide powder with a depth of 100 μm from the tip surface so that the irradiated low laser energy could be perfectly absorbed to be transferred to thermal energy. Thus, the laser treatment can be performed without suffering from any optical characteristic of the material. A semiconductor laser was operated quasi-continuous wave mode pulse time duration of 180 ms and >95% of the laser energy was converted to thermal energy in the fiber tip. Based on two-color thermometry, by using a gated optical multichannel analyzer with a 0.25 m spectrometer in visible wavelength region, the temperature of the fiber tip was analyzed. The temperature of the heat source was measured to be in excess 3100 K.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving the Thermal Characteristics of Semiconductor Lasers Using a New Asymmetric Waveguide Structure

   Self-heating leads to a temperature rise of the laser diode and limits the output power and efficiency due to increased loss and decreased differential gain. To control device self-heating, it is required to design the laser structure with a low optical loss, while the heat flux must spread out of the device efficiently. In this study, a new asymmetric waveguide design is proposed and th...

متن کامل

Continuous-wave quasi-phase-matched generation of 60 mW at 465 nm by single-pass frequency doubling of a laser diode in backswitch-poled lithium niobate.

We report continuous-wave single-pass second-harmonic generation (SHG) in 4-mum -period 0.5-mm-thick backswitch-poled lithium niobate. Pump sources at 920-930 nm include both Ti:sapphire and diode-oscillator-amplifier lasers. SHG of a Ti:sapphire laser at 6.1%/W efficiency, producing 61 mW of power at 460 nm, is demonstrated in 50-mm-long periodically poled lithium niobate samples with a nonlin...

متن کامل

Design and implementation of high voltage square wave power source with variable DC-offset and study its effect on atmospheric-pressure plasma

Nowadays high-voltage power sources is used in different areas such as generation of atmospheric-pressure plasma. Different voltage waveforms affect the plasma generation and its quality. In this paper a new high voltage square wave with DC-offset power source is presented to study the different parameters on plasma generation and propagation. The proposed converter which is based on power semi...

متن کامل

Mid-infrared trace gas detection using continuous-wave difference frequency generation in periodically poled RbTiOAsO4.

A tunable mid-infrared continuous-wave (cw) spectroscopic source in the 3.4-4.5 micrometers region is reported, based on difference frequency generation (DFG) in a quasi-phase-matched periodically poled RbTiOAsO4 (PPRTA) crystal. DFG power levels of 10 microW were generated at approximately 4 micrometers in a 20-mm long PPRTA crystal by mixing two cw single-frequency Ti:Al2O3 lasers operating n...

متن کامل

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 19 10  شماره 

صفحات  -

تاریخ انتشار 2014