Consistency of T1ρ Measurements: A Phantom Study

نویسندگان

  • D. R. Thedens
  • N. F. Klocke
  • J. A. Martin
  • T. E. Baer
  • D. R. Pedersen
چکیده

Introduction: Magnetic resonance imaging (MRI) remains the primary standard for visualization of cartilage defects and overall assessment of cartilage morphology. As the initial stages of osteoarthritis (OA) arise from biochemical changes at the tissue level such as proteoglycan (PG) loss, the standard contrast mechanisms acquired as part of routine clinical MRI protocols are not typically sensitive to hallmarks of early OA. A number of MRI-based methods have been developed and studied for their potential to serve as imaging biomarkers for these early changes. Examples include T2 mapping to evaluate collagen matrix integrity[1], and dGEMRIC [2] and T1ρ [3-4] imaging to assess proteoglycan depletion. Among these methods, T1ρ imaging has held particular interest as it has demonstrated sensitivity to PG content (the primary target of dGEMRIC) while being straightforward to apply without the need for an exogenous contrast agent (like T2 mapping). T1ρ relaxation times are reflective of the lowfrequency interactions between water and macromolecules, such as PG. These interactions are probed by preparing the magnetization with low power but relatively lengthy RF pulses prior to a repetition of a standard MR pulse sequence (typically a spin-echo or gradient-echo-based acquisition). Ideally, T1ρ relaxation times should not depend on the scanner or coil hardware used to acquire the images. However, variations in the main (B0) field as well as the RF pulses (B1) over the volume of the coil may affect the quantification of T1ρ maps acquired on different hardware. These variations may complicate T1ρ assessment of cartilage degradation in populations or series acquired on a variety of hardware. The purpose of this study was to assess the consistency of T1ρ measurements across multiple acquisition platforms in a controlled phantom study. Methods: A purpose-built phantom was designed and constructed to assess pulse sequence and artifact conditions across MR imaging sequences and platforms specifically for imaging protocols in the knee (Figure 1). The phantom consisted of concentric Plexiglas rings separating compartments filled with a mixture of carrageenan and agarose gel and doped with gadolinium trichloride (GdCl3). As described in Figure 1, the concentrations of agarose and GdCl were varied to generate gels having T1ρ relaxation times over a range similar to that for cartilage. The central core was filled with lipid material (lard). The dimensions of the phantom were designed to fit inside and fully load typical extremity coils used for joint imaging. Identical T1ρ imaging protocols were acquired on each of two 3T Siemens TIM Trio scanners, utilizing each of two transmit-receive extremity coils (one single-channel CP coil, one 15 channel coil) for a total of four complete imaging sessions. For all sessions, the pulse sequence consisted of a T1ρ preparation block applied to a fast spin echo pulse sequence with TR/TE=3000/12 ms, echo train length of 7, and 256 x 128 matrix over 3 slices. The T1ρ block consisted of a 90° square tip-down pulse, 400 Hz spin lock pulse of four different durations (10, 20, 40, and 60 ms, implemented as in [5] to minimize B1 inhomogeneity effects), a -90° tip-up pulse, and a final crusher gradient. The acquisition plane was oriented sagittally with a field of view of 160 x 160 mm and slice thickness of 4 mm, equivalent to a typical in vivo protocol. For each session, tuning with a 3D shim procedure was followed by the four spin-lock time acquisitions. To further assess the effects of B0 changes, the central acquisition frequency was adjusted over a range of ±25 Hz with all other parameters held equal, yielding four additional T1ρ data sets for each session. Nonlinear curve fitting estimated the T1ρ relaxation time at each pixel location within a manually identified 10 x 160 pixel region of interest within each ring of the gel phantom in each of the 3 slices, yielding two measurements for each of the five gels at distinct spatial locations. Mean T1ρ values were computed over these manually selected regions for each scanner/coil combination, gel, slice, and each frequency setting.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Myocardial T1ρ with a Motion Corrected, Parametric Mapping Sequence in Humans

PURPOSE To develop a robust T1ρ magnetic resonance imaging (MRI) sequence for assessment of myocardial disease in humans. MATERIALS AND METHODS We developed a breath-held T1ρ mapping method using a single-shot, T1ρ-prepared balanced steady-state free-precession (bSSFP) sequence. The magnetization trajectory was simulated to identify sources of T1ρ error. To limit motion artifacts, an optical ...

متن کامل

Characterization of non-hemodynamic functional signal measured by spin-lock fMRI

Current functional MRI techniques measure hemodynamic changes induced by neural activity. Alternative measurement of signals originated from tissue is desirable and may be achieved using T1ρ, the spin-lattice relaxation time in the rotating-frame, which is measured by spin-lock MRI. Functional T1ρ changes in the brain can have contributions from vascular dilation, tissue acidosis, and potential...

متن کامل

Interobserver and Test-Retest Reproducibility of T1ρ and T2 Measurements of Lumbar Intervertebral Discs by 3T Magnetic Resonance Imaging

OBJECTIVE To investigate the interobserver and test-retest reproducibility of T1ρ and T2 measurements of lumbar intervertebral discs using 3T magnetic resonance imaging (MRI). MATERIALS AND METHODS This study included a total of 51 volunteers (female, 26; male, 25; mean age, 54 ± 16.3 years) who underwent lumbar spine MRI with a 3.0 T scanner. Amongst these subjects, 40 underwent repeat T1ρ a...

متن کامل

T1ρ Dispersion in Articular Cartilage

Objective. This study assessed T1ρ relaxation dispersion, measured by magnetic resonance imaging (MRI), as a tool to noninvasively evaluate cartilage material and biochemical properties. The specific objective was to answer two questions: (1) does cartilage initial elastic modulus (E 0 ) correlate with T1ρ dispersion effects and (2) does collagen or proteoglycan content correlate with T1ρ dispe...

متن کامل

T1ρ Dispersion in Articular Cartilage: Relationship to Material Properties and Macromolecular Content.

OBJECTIVE This study assessed T1ρ relaxation dispersion, measured by magnetic resonance imaging (MRI), as a tool to noninvasively evaluate cartilage material and biochemical properties. The specific objective was to answer two questions: (1) does cartilage initial elastic modulus (E 0) correlate with T1ρ dispersion effects and (2) does collagen or proteoglycan content correlate with T1ρ dispers...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010