The 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE) trial: study protocol for a randomized controlled trial

نویسندگان

  • Kyung Woo Park
  • Byoung-Eun Park
  • Si-Hyuck Kang
  • Jin-Joo Park
  • Seung-Pyo Lee
  • Kwang Soo Cha
  • Jay Young Rhew
  • Hui-Kyoung Jeon
  • Eun Seok Shin
  • Ju Hyeon Oh
  • Myung-Ho Jeong
  • Sanghyun Kim
  • Kyung-Kuk Hwang
  • Jung-Han Yoon
  • Sung Yun Lee
  • Tae-Ho Park
  • Keon Woong Moon
  • Hyuck-Moon Kwon
  • In-Ho Chae
  • Hyo-Soo Kim
چکیده

BACKGROUND Second-generation drug-eluting stents (DES) have raised the bar of clinical performance. These stents are mostly made from cobalt chromium alloy. A newer generation DES has been developed from platinum chromium alloy, but clinical data regarding the efficacy and safety of the platinum chromium-based everolimus-eluting stent (PtCr-EES) is limited, with no comparison data against the cobalt chromium-based zotarolimus-eluting stent (CoCr-ZES). In addition, an antiplatelet regimen is an integral component of medical therapy after percutaneous coronary intervention (PCI). A 1-week duration of doubling the dose of clopidogrel (double-dose antiplatelet therapy (DDAT)) was shown to improve outcome at 1 month compared with conventional dose in acute coronary syndrome (ACS) patients undergoing PCI. However in Asia, including Korea, the addition of cilostazol (triplet antiplatelet therapy (TAT)) is used more commonly than doubling the dose of clopidogrel in high-risk patients. METHODS In the 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE) trial, approximately 3,750 patients are being prospectively and randomly assigned in a 2 × 2 factorial design according to the type of stent (PtCr-EES vs CoCr-ZES) and antiplatelet regimen (TAT vs DDAT). The first primary endpoint is target lesion failure at 1 year for the stent comparison, and the second primary endpoint is net clinical outcome at 1 month for comparison of antiplatelet therapy regimen. DISCUSSION The HOST-ASSURE trial is the largest study yet performed to directly compare the efficacy and safety of the PtCr-EES versus CoCr-ZES in an 'all-comers' population. In addition, this study will also compare the clinical outcome of TAT versus DDAT for 1-month post PCI. TRIAL REGISTRATION ClincalTrials.gov number NCT01267734.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study protocol for a randomised controlled trial: harmonising optimal strategy for treatment of coronary artery stenosis — coronary intervention with next-generation drug-eluting stent platforms and abbreviated dual antiplatelet therapy (HOST-IDEA) trial

INTRODUCTION We have recently seen the introduction of newer generation drug-eluting stents with ultrathin struts that use advanced polymer technologies. However, the efficacy and safety of these newest stents have not yet been fully explored. In addition, there are still controversies over the optimal duration of dual antiplatelet therapy (DAPT) after stent implantation, particularly for ultra...

متن کامل

Efficacy and safety of 12 versus 48 months of dual antiplatelet therapy after implantation of a drug-eluting stent: the OPTImal DUAL antiplatelet therapy (OPTIDUAL) trial: study protocol for a randomized controlled trial

BACKGROUND Dual antiplatelet therapy with aspirin and thienopyridine is required after placement of coronary drug-eluting stents (DES) to prevent thrombotic complications. Current clinical guidelines recommend at least 6 to 12 months of treatment after a DES implantation, but it may be beneficial to apply dual antiplatelet therapy for a longer duration. METHODS/DESIGN The optimal dual antipla...

متن کامل

Angiographic and clinical comparison of novel Orsiro Hybrid sirolimus-eluting stents and Resolute Integrity zotarolimus-eluting stents in all-comers with coronary artery disease (ORIENT trial): study protocol for a randomized controlled trial

BACKGROUND The Orsiro Hybrid sirolimus-eluting stent is a newly developed third-generation drug-eluting stent, featuring a unique dual-polymer mix. An active bioabsorbable polymer delivers the anti-proliferative drug, sirolimus, via controlled release, while a passive biocompatible polymeric coating shields the metallic strut from surrounding tissue, preventing interaction. To date, the Orsiro ...

متن کامل

Cigarette Smoking Does Not Enhance Clopidogrel Responsiveness After Adjusting VerifyNow P2Y12 Reaction Unit for the Influence of Hemoglobin Level.

OBJECTIVES The authors performed this analysis to examine whether the enhanced clopidogrel responsiveness in current smokers is maintained after adjusting the influence of hemoglobin on VerifyNow P2Y12 reaction unit (PRU). BACKGROUND PRU is consistently reported to be lower in current smokers. However, PRU has a significant inverse relationship with hemoglobin level, and smokers have higher h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2012