High-resolution x-ray CT scanning of the human stapes footplate

نویسندگان

  • Abdulrahman A. Hagr
  • Robert J. Funnell
  • Anthony G. Zeitouni
  • Jamie M. Rappaport
چکیده

Objectives: The mechanical behaviour of the footplate and its annular ligament depends critically on their shape and orientation in the oval window, but accurate measurements have been difficult to make due to their small size. Our aims are to visualize the footplate at high resolution and understand its dynamics. Methods: The human cadaver stapes footplate was dissected and very high resolution x-ray CT scans, with voxel sizes from 4 to 8 μm, were performed. Locally developed software was used to reconstruct the images. Results: The data permit us to explore minor details of shape and orientation. The footplate looks like a footprint, and the annular ligament has variable thickness with a cleft ( groove ) in its anterior attachment to the oval window. The CT data also permit us to create a 3-D finite-element model which can simulate footplate motion. Conclusions: The results obtained lead to further understanding of the mechanical behaviour of the footplate and the annular ligament. Author

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution X-ray computed tomographic scanning of the human stapes footplate.

OBJECTIVES The mechanical behaviour of the footplate and its annular ligament depends critically on their shape and orientation in the oval window, but accurate measurements have been difficult to make owing to their small size. Our aims are to visualize the footplate at high resolution and understand its dynamics. METHODS The human cadaver stapes footplate was dissected, and very high-resolu...

متن کامل

A Rare Stapes Abnormality

The aim of this study is to increase awareness of rare presentations, diagnostic difficulties alongside management of conductive hearing loss and ossicular abnormalities. We report the case of a 13-year-old female reporting progressive left-sided hearing loss and high resolution computed tomography was initially reported as normal. Exploratory tympanotomy revealed an absent stapedius tendon and...

متن کامل

Oval window niche height: quantitative evaluation with CT before stapes surgery for otosclerosis.

BACKGROUND AND PURPOSE Stapes surgery for otosclerosis can be challenging when the oval window niche is narrow. We analyzed the reliability of CT to evaluate the height of the OWN and propose a quantitative criterion to distinguish normal and narrow OWNs. MATERIALS AND METHODS Fifty-six patients were scheduled for primary stapes surgery and, with available preoperative CT scans, were prospect...

متن کامل

Reliability of high-resolution CT scan in diagnosis of otosclerosis.

OBJECTIVE To assess the reliability of high-resolution computed tomographic scan (HRCT scan) for the diagnosis of otosclerosis and to determine its usefulness to predict hearing deterioration and surgical difficulties. STUDY DESIGN Prospective study. SETTING Tertiary reference center. PATIENTS Two hundred nine ears (200 patients) presenting progressive conductive hearing loss with normal ...

متن کامل

The effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner

Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005