Usefulness of low dose chest CT for initial evaluation of blunt chest trauma: Erratum

نویسندگان

  • Sung Jung Kim
  • Anjali Basnyat Bista
  • Young Gi Min
  • Eun Young Kim
  • Kyung Joo Park
  • Doo Kyoung Kang
  • Joo Sung Sun
چکیده

We aimed to compare the diagnostic performance and inter-observer consistency between low dose chest CT (LDCT) and standard dose chest CT (SDCT) in the patients with blunt chest trauma.A total of 69 patients who met criteria indicative of blunt chest trauma (77% of male; age range, 16-85) were enrolled. All patients underwent LDCT without intravenous (IV) contrast and SDCT with IV contrast using parameters as following: LDCT, 40 mAs with automatic tube current modulation (ATCM) and 100 kVp (BMI <25, n = 51) or 120 kVp (BMI>25, n = 18); SDCT, 180 mAs with ATCM and 120 kVp. Transverse, coronal, sagittal images were reconstructed with 3-mm slice thickness without gap and provided for evaluation of 3 observers. Reference standard images (transverse, coronal, sagittal) were reconstructed using SDCT data with 1-mm slice thickness without gap. Reference standard was established by 2 experienced thoracic radiologists by consensus. Three observers independently evaluated each data set of LDCT and SDCT.Multiple-reader receiver operating characteristic analysis for comparing areas under the ROC curves demonstrated that there was no significant difference of diagnostic performance between LDCT and SDCT for the diagnosis of pulmonary injury, skeletal trauma, mediastinal injury, and chest wall injury (P > 0.05). The intraclass correlation coefficient was measured for inter-observer consistency and revealed that there was good inter-observer consistency in each examination of LDCT and SDCT for evaluation of blunt chest injury (0.8601-1.000). Aortic and upper abdominal injury could not be appropriately compared as LDCT was performed without using contrast materials and this was limitation of this study.The effective radiation dose of LDCT (average DLP = 1.52 mSv⋅mGy cm) was significantly lower than those of SDCT (7.21 mSv mGy cm).There is a great potential benefit to use of LDCT for initial evaluation of blunt chest trauma because LDCT could maintain diagnostic image quality as SDCT and provide significant radiation dose reduction. A further study of LDCT with IV contrast for evaluation of aortic and upper abdominal injury is needed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unusual Presentation of Pulmonary Hematoma after Blunt Chest Wall Trauma

A 25-year-old man was admitted in hospital due to right side hemopneumothorax secondary to car accident. A chest tube was inserted. During the hospitalization days, chest CT scan revealed a 3cmx3 cm oval-shaped density located in the right upper lobe. Since he was in a good general condition, he was discharged from hospital after removal of chest tube and a follow-up chest CT-scan was recommend...

متن کامل

Routine initial computed tomography of the chest in blunt torso trauma.

Computer tomography (CT) is an effective technique in the initial evaluation of the abdomen and head following blunt trauma. To evaluate the role of CT of the thorax, a prospective study comparing routine early thoracic CT scanning with initial chest roentgenogram (CXR) was carried out on 73 patients with blunt torso trauma undergoing concomitant abdominal CT examination. Initial CXR and CT sca...

متن کامل

Evaluation of PERSH Criteria to Avoid Unnecessary Chest X-ray in Patients with Blunt Chest Trauma: A Qualitative Study

Background: Chest X-rays (CXRs) are traditionally performed to determine intra-thoracic injuries in all blunt chest trauma patients in Shahid Bahonar hospital in Kerman. As there are some disadvantages upon CXR and radiation exposure, therefore, this study aimed to evaluate the role of CXR in the diagnosis of intra-thoracic injuries caused by any blunt chest trauma. Me...

متن کامل

Clinical Value of Low Dose CT- Scan in Pediatric Chest Diseases: Adequacy Assessment

Background Radiation dose about 400 times that of standard thoracic computed tomography (CT) in comparison with chest X- ray resulting in different approaches to decrease radiation dose have been established in the last few years to prevent possible side effects especially in children, such as low dose protocols. The aim of this study was assessment of clinical v...

متن کامل

Reconstruction of Large Airways Following Main Bronchial Rapture a Year after Blunt Trauma

We present the case of a 19-year-old boy with a history of breathlessness and blunt chest trauma one year ago. Figure 1 show CT scan of patient. Figure 2: show bronchoscopic of patient. Figure 3 and 4 show intra operative view and Fig 5 show CXR of patient after surgery

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2017