Measurement of Beam Characteristics for Photo- Electron Beam at Waseda University *

نویسندگان

  • R. Kuroda
  • M. Washio
  • S. Kashiwagi
  • T. Oshima
  • J. Urakawa
  • H. Hayano
  • X. J. Wang
چکیده

The low emittance and short pulse electron beam is expected to be used in a wide field, such as X-ray generation by inverse Compton scattering, pulse radiolysis, etc. The laser driven photo cathode rf gun system is possible to produce the low emittance and short pulse electron beam [1]. It is very important for generating the low emittance and short pulse electron beam to measure the beam characteristics such as the bunch length precisely. In this report, the measurement system of the bunch length using frequency analysis for the photoelectron beam generated by the rf gun and results of the preliminary experiment at KEK-ATF (Accelerator Test Facility) Linac is described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

All-solid-state Picosecond Laser System for Photo Cathode Rf-gun and X-ray Generation at Waseda University

An 1.6 cell rf-gun system has been installed at Waseda University for the generation of high charge, short pulse and low emittance electron beam. The gun is one of essential component for X-ray generation using inverse Compton scattering between photo electron bunch and laser pulse. An all-solid-state picosecond Nd:YLF laser system has been installed at Waseda University and will be used not on...

متن کامل

Present Status of Rf Gun Project at Waseda University

We have conducted the research project named “HighTech Research Center Project” at Waseda University, which is supported by the Ministry of Education, Culture, Sports, Science and Technology. In this project, a laser photo-cathode rf-gun with 1.6 acceleration cells with Mg cathode has been installed for production of low emittance and short bunched electron beam. Main parts of rf source for the...

متن کامل

Physical characteristics of electron beam from conventional and beam shaper IOERT applicator: A comparison study

Introduction: Intraoperative electron radiation therapy (IOERT) is one of the cancer treatment techniques that delivers high doses to tumor bed during surgery. IOERT can be performed by either conventional LINACs or dedicated IORT accelerators such as LIAC (Light Intraoperative Accelerator). Two types of applicators can be used with LIAC dedicated accelerator including conventi...

متن کامل

Benchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement

Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator.   Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...

متن کامل

Effect of photo–electron therapy on human neoplastic cells

Background: Cancer is a complex disease with high rate of mortality. At present, Radiation therapy is one of the most common procedures to overcome this situation. The deficiency of conventional method is the lack of fatal dose transmission into the malignant tissue. Hence, uncertain dose may cause regeneration of cancer cells, and relapse of the disease and invasion of the cancer cells to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001