What sample sizes are needed to get correct significance levels for log-linear models? - A Monte Carlo Study using the SPSS-procedure "Hiloglinear"

نویسنده

  • Ingeborg STELZL
چکیده

Pearson's 2 ! and the Likelihood-ratio statistic 2 G are the most common and widely used test statistics for log-linear models. They are both asymptotically distributed as chi-squared variables. The present article reports the results of a Monte-Carlo study which compares the two test statistics for two-, threeand four-dimensional contingency tables, employing conditions which may be judged reasonable for psychological research and using one of the most prominent computer programs (SPSS "Hiloglinear"). Our results are consistent with previous research in that, on the whole, Pearson's 2 ! behaves better than 2 G . As a rule of thumb one may state that Pearson's 2 ! will not result in severely inflated alpha values (empirical values of .075 or larger for a nominal level of .05) if the total sample size equals five times the number of cells and the smallest expected cell frequency is larger than 0.50. On contrast, the Likelihood-ratio statistic 2 G yields in some cases severely inflated empirical alpha values for the higher interactions even if the total sample size equals ten times the number of cells and the smallest expected cell frequency is larger than one. In those cases where sample size is large enough to use Pearson's 2 ! , Pearson's 2 ! is preferable to 2 G , as it is generally closer to the nominal alpha. For cases not covered by this rule parametric bootstrapping is recommended.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Benchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement

Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator.   Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...

متن کامل

Developement a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code

Background: Monte Carlo (MC) modeling of a linear accelerator is a prerequisite for Monte Carlo dose calculations in external beam radiotherapy. In this study, a simple and efficient model was developed for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code Materials and methods: The head of Elekta SL-25 linac was simulated for 6 and 18 MV photon beams using MCNP4C MC code. Energ...

متن کامل

Monte Carlo Simulation of a Linear Accelerator and Electron Beam Parameters Used in Radiotherapy

Introduction: In recent decades, several Monte Carlo codes have been introduced for research and medical applications. These methods provide both accurate and detailed calculation of particle transport from linear accelerators. The main drawback of Monte Carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...

متن کامل

Spatial count models on the number of unhealthy days in Tehran

Spatial count data is usually found in most sciences such as environmental science, meteorology, geology and medicine. Spatial generalized linear models based on poisson (poisson-lognormal spatial model) and binomial (binomial-logitnormal spatial model) distributions are often used to analyze discrete count data in which spatial correlation is observed. The likelihood function of these models i...

متن کامل

The comparison between 6 MV Primus LINAC simulation output using EGSnrc and commissioning data

Introduction: Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy. The purpose of this research is comparison between 6 MV Primus LINAC simulation output with commissioning data using EGSnrc and build a Monte Carlo geometry of 6 MV Primus LINAC as realistically as possible. The BEAMnrc and DOSXYZnrc (EGSnrc package) M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001