Water quality-based real time control of integrated urban drainage systems: a preliminary study from Copenhagen, Denmark

نویسندگان

  • L. Vezzaro
  • M. L. Christensen
  • C. Thirsing
  • M. Grum
  • P. S. Mikkelsen
چکیده

Global Real Time Control (RTC) of urban drainage systems is increasingly seen as cost-effective solution for responding to increasing performance demands. This study investigated the potential for including water-quality based RTC into the global control strategy which is under implementation in the Lynetten catchment (Copenhagen, Denmark). Two different strategies were simulated, considering: (i) water quality at the wastewater treatment plant (WWTP) inlet and (ii) pollution discharge to the bathing areas. These strategies were included in the Dynamic Overflow Risk Assessment (DORA) RTC strategy, which allows for prioritization of the discharge points in the systems according to their sensitivity. A conceptual hydrological model was used to assess the performance of the integrated control strategy over an entire year. The simulation results showed the benefits of the proposed approaches in reducing Combined Sewer Overflow (CSO) loads at the WWTP inlet and in an upstream location discharging to sensitive bathing waters for medium CSO events (i.e. those with greater potential for control). Furthermore, when looking at the overall performance across the entire catchment during the simulation period, no significant changes were observed. These preliminary results require further analysis by including detailed water quality measurements and simulations. Nevertheless, the potential for including water-quality RTC in global RTC schemes was unveiled, providing a further option to urban water managers to improve the performance of their systems. © 2013 The Authors. Published by Elsevier Ltd. Selection and peer-review under responsibility of the CCWI2013 Committee.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-Time Control-Oriented Quality Modelling in Combined Urban Drainage Networks?

Urban drainage networks (UDN) carry urban wastewater to wastewater treatment plants (WWTP) in order to regenerate it before releasing it to the environment. Combined UDN (CUDN) carry both rain and wastewater together, which can overload the UDN and produce combined sewer overflows (CSO) that pollute the environment. Management of CUDN is receiving increasing attention from both researchers and ...

متن کامل

Real-Time Control of Urban Water Systems

This paper presents a review of the current state of the art of real time control (RTC) of urban water systems with emphasis on wastewater and urban drainage issues. The paper provides concise definitions of terms frequently used in the literature. Control options for the transport and treatment systems are discussed. Recent developments of the integration of the complete urban wastewater and d...

متن کامل

Persistent Organic Pollutants in Fresh Water Ecosystems

1 College of Urban and Environmental Sciences, Peking University, Beijing 100871, China 2Department of Environmental Chemistry, Institute of Analytical and Pharmaceutical Chemistry, Copenhagen University, 2100 Copenhagen Ø, Denmark 3 Research Center for Environmental Quality Control, Kyoto University, Otsu, Kyoto 520-0811, Japan 4 Institute of Biology, Irkutsk State University, Irkutsk 664003, ...

متن کامل

Modelling of Urban Flooding in Dhaka City

Flooding in urban areas is an inevitable problem for many cities in Asia. In Bangladesh, Dhaka has serious problems related to urban flooding. The situation was highlighted in September 1996 when residences experienced ankle to kneedeep water on the streets. Daily activities in parts of the city were nearly paralyzed and heavy traffic jams occurred due to stagnant water on the streets. The stud...

متن کامل

Assessment of household reverse-osmosis systems in heavy metal and solute ion removal in real and synthetic samples

In this study, the efficiency of household reverse-osmosis system (HROS) with and without neutralizer accessory was investigated in both real and synthetic samples. The real samples were collected from rural and urban public drinking-water systems with and without primary refinery treatment. The selected areas were situated in the Kurdistan province, Iran. The HROS model RO100GPD with and witho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014