Three dimensional nuchal translucency assessment using magnetic resonance reconstruction imaging
نویسندگان
چکیده
Lai Khin Wee1,2*, Hum Yan Chai3 and Eko Supriyanto2 1Biomedical Engineering Department, Faculty of Computer Science and Automation, Institute of Biomedical Engineering and Informatics, Technische Universität Ilmenau, 98684, Ilmenau, Thuringia, Germany 2Department of Clinical Science and Engineering, 3Department of Biomedical Instrumentation and Signal Processing, Faculty of Health Science and Biomedical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor, Malaysia
منابع مشابه
Measurement of fetal nuchal translucency thickness by three-dimensional ultrasound.
OBJECTIVE To investigate the feasibility and repeatability of nuchal translucency thickness measurement using three-dimensional ultrasound. METHODS Forty consecutive women with uncomplicated singleton pregnancies attending for Down syndrome screening at 11-14 weeks' gestation were included in this prospective crossover trial. Nuchal translucency thickness was measured using both two-dimension...
متن کاملI-42: Advanced Ultrasonic Techniques in The Assessment of Early Human Development
Background: To evaluate the role of 3D, 4D and color Doppler ultrasound (US) in the assessment of early human development. Materials and Methods: 380 women with uncomplicated early pregnancy between 5 and 14 weeks were evaluated by 3D, 4D and color Doppler US. Results: Regression analysis revealed exponential rise of the gestational sac volume with gestational age throughout the first trimester...
متن کاملFirst-Trimester Detection of Down Syndrome Using Fetal Ultrasound Markers Combined with Maternal Serum Assessment
Note: It should be noted that appropriate training of ultrasonographers with ongoing quality assurance programs are considered critical to the accurate measurement of fetal nuchal translucency. In addition, in published studies of first trimester screening, the laboratory and imaging components of screening (i.e., fetal nuchal translucency and measurement of maternal serum factors) are performe...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملComparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments.
Current two-dimensional (2D) ultrasonic marker measurements are inherent with intra- and inter-observer variability limitations. The objective of this paper is to investigate the performance of conventional 2D ultrasonic marker measurements and proposed programmable interactive three-dimensional (3D) marker evaluation. This is essentially important to analyze that the measurement on 3D volumetr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012