Ultrasound assessment of normal hemidiaphragmatic movement: relation to inspiratory volume.
نویسندگان
چکیده
BACKGROUND Traditionally the radiological assessment of diaphragmatic movement has relied on fluoroscopy. Ultrasound scanning has recently been shown to be a sensitive and reproducible method of assessing hemidiaphragmatic movement in normal subjects. A study was undertaken to examine how movement of the diaphragm measured by ultrasound scanning relates to inspired lung volumes measured by spirometric testing. METHODS Ultrasound examinations were performed on 14 normal volunteers using a 3.5 MHz sector transducer (Acuson 128). A fixed skin position on each lateral chest wall between the anterior clavicular and midaxillary line was selected symmetrically to obtain a longitudinal plane of each hemidiaphragm including the maximal renal bipolar length, allowing identification of the adjacent posterior aspect of the diaphragm. Craniocaudal excursions of the posterior part of each hemidiaphragm on successive respiratory cycles were recorded on videotape and compared with spirometric measurements recorded simultaneously on a water bath spirometer. Measurements were made in the sitting and supine position and were repeated on a separate occasion (at least two weeks apart) in 10 subjects by the same operator to assess reproducibility. RESULTS The relation between inspired volume and hemidiaphragmatic movement was found to be linear. The gradient of these observed linear relations (hemidiaphragmatic excursion (mm)/inspired volume (1)) was calculated and their distribution for each hemidiaphragm followed a normal distribution irrespective of position. The 95% confidence limits of the right to left ratio of these gradients in the supine position were 0.53 and 1.7. Change of posture from the supine to the sitting position reduced the gradient. The technique had acceptable reproducibility with coefficients of variation for the supine position of 7.5% and 11.7% for right and left hemidiaphragm respectively. CONCLUSION Ultrasound scanning is a simple, non-invasive and reproducible means of assessing hemidiaphragmatic movement, yielding quantitative information which relates to inspired lung volumes.
منابع مشابه
Abdominal wall movement in normals and patients with hemidiaphragmatic and bilateral diaphragmatic palsy.
Abdominal wall movement in normals and patients with hemidiaphragmatic and bilateral diaphragmatic palsy. The abdomen and ribcage volume contribution to the tidal volume have been determined using magnetometers in three groups of subjects-normal males, patients with hemidiaphragmatic palsy, and patients with bilateral diaphragmatic palsy. In all three groups the main moving parts appear to be t...
متن کاملExcursion-volume relation of the right hemidiaphragm measured by ultrasonography and respiratory airflow measurements.
BACKGROUND Although real time ultrasonography has been used in the last decade to record diaphragmatic motion, the relation between diaphragmatic excursion and different inspired volumes (VT) has not been assessed by ultrasound. METHODS Ten normal subjects were studied in the supine posture. Diaphragmatic excursion and VT were assessed simultaneously by M mode ultrasonography and respiratory ...
متن کاملIn vivo assessment of diaphragm contraction by ultrasound in normal subjects.
BACKGROUND Ultrasound allows observation of the thickness of the diaphragm in the zone of apposition in vivo during relaxation and maximum inspiratory efforts. METHODS Changes of diaphragm thickness were studied by B mode (two dimensional) ultrasound in 13 healthy men aged 29-54 years in the seated position. A high resolution 7.5 MHz ultrasound transducer was held perpendicular to the chest w...
متن کاملClinical Comparison of Two Different Volumes of 0.5% Bupivacaine for Clavicular Surgeries Using Combined Interscalene and Superficial Cervical Plexus Block
Context: The use of ultrasound in regional anaesthesia has resulted in reduction in local anaesthetic volume and adverse effects. Aim : This study aims to compare the quality of analgesia and incidence of adverse effects using two different volumes of 0.5 % bupivacaine for clavicular surgeries by ultrasound guided combined interscalene and superficial cervical plexus block. Settings and Design:...
متن کاملTwo-dimensional strain ultrasound speckle tracking as a novel approach for the evaluation of right hemidiaphragmatic longitudinal deformation
The diaphragm is an important respiratory organ. The aim of this study was to quantitatively evaluate the longitudinal deformation of the right hemidiaphragm in normal subjects using two-dimensional strain ultrasound speckle tracking. Twenty-one healthy subjects were enrolled in this study. GE Healthcare Vivid E9 equipment with M5S probe and Q-analysis software were used. Negative strain values...