A 42-year-old patient presenting with femoral head migration after hemiarthroplasty performed 22 years earlier: a case report

نویسندگان

  • Akio Kanda
  • Kazuo Kaneko
  • Osamu Obayashi
  • Atsuhiko Mogami
چکیده

INTRODUCTION Treatment of femoral neck fractures in young adults may require total hip arthroplasty or hip hemiarthroplasty using a bipolar cup. The latter can, however, result in migration of the femoral head and poor long-term results. CASE PRESENTATION We report a case of femoral head migration after hemiarthroplasty performed for femoral neck fracture that had occurred 22 years earlier, when the patient (a Japanese man) was 20 years old. He experienced peri-prosthetic fracture of the femur, subsequent migration of the prosthesis, and a massive bone defect of the pelvic side acetabular roof. After bone union of the femoral shaft fracture, the patient was referred to our hospital for reconstruction of the acetabular roof. Intra-operatively, we placed two alloimplants of bone from around the transplanted femoral head into the weight-bearing region of the acetabular roof using an impaction bone graft method. We then implanted an acetabular roof reinforcement plate and a cemented polyethylene cup in the position of the original acetabular cup. Eighteen months post-operatively, X-rays showed union of the transplanted bone. CONCLUSIONS Treatment of femoral neck fractures in young adults is usually accomplished by osteosynthesis, but it may be complicated by femoral head avascular necrosis or by infection or osteomyelitis. In such cases, once an infection has subsided, either hip hemiarthroplasty using a bipolar cup or total hip arthroplasty may be required. However, if the acetabular side articular cartilage is damaged, a bipolar cup should not be used. Total hip arthroplasty should be performed to prevent migration of the implant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lupus Vulgaris of the Pinna-A Case Report

Introduction: Lupus vulgaris is the most common form of cutaneous tuberculosis caused by contiguous spread from an underlying infective focus or lymphatic or hematogenous spread. It can also develop at the site of direct inoculation (e.g., tattooing and ear piercing) or Bacillus Calmette-Guerin vaccination. The solitary involvement of the pinna is rare and may face clinicians with a diagn...

متن کامل

An Otogenic Trapezius Abscess: A Case Report

Introduction: An otogenic brain abscess is a common ENT problem but an otogenic trapezius abscess can also be experienced in otolaryngological practice, particularly in patients with chronic suppurative otitis media.   Case Report: We report a rare case of a trapezius abscess in an eight-year-old girl who presented at the ENT, Head and Neck Surgery Postgraduate Medical Institute, Lady Readi...

متن کامل

Bilateral subcapital femoral neck fractures secondary to transient osteoporosis during pregnancy: a case report.

Transient osteoporosis during pregnancy is a rare, self-limiting disease. We report on a 36-year-old woman who had bilateral subcapital femoral neck fractures during the 6th month of pregnancy. The diagnosis was made 4 days after delivery, because radiography was declined by the patient for fear of radiation. Fixation was not feasible owing to bone resorption, and 2-stage bipolar hemiarthroplas...

متن کامل

Hemi-arthroplasty performed in a 109-year-old patient with intertrochanteric fracture: A case report

The mortality of conservative treatment and the risk resulting from operation for elderly patients with femoral intertrochanteric fractures are high. Safety in the perioperative period and quicker recovery should be placed at the top priority for elderly patients with hip fractures. We reported a case of 109-year-old female patient with intertrochanteric fracture who has undergone the hemiarthr...

متن کامل

Corrosion and adverse tissue reaction after modular unipolar hip hemiarthroplasty

Modern unipolar hip hemiarthroplasty, commonly used for displaced femoral neck fracture, is now modular, with both a variable length cobalt-chromium adapter-sleeve and large femoral head. Patients with these modular components may develop symptomatic trunnion corrosion, with elevated serum metal levels. We report the case of an 82-year-old woman, 5.5 years after a modular unipolar hip hemiarthr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015