Magnetic Resonance Imaging Compatibility of the Polymer-based Cochlear Implant

نویسندگان

  • Jin Ho Kim
  • Kyou Sik Min
  • Soon Kwan An
  • Joon Soo Jeong
  • Sang Beom Jun
  • Min Hyoung Cho
  • Young-Don Son
  • Zang-Hee Cho
  • Sung June Kim
چکیده

OBJECTIVES In this study, we compared the magnetic resonance (MR) image artifacts caused by a conventional metal-based cochlear implant and a newly developed liquid crystal polymer (LCP)-based device. METHODS The metal-based cochlear implant system (Nurobiosys Co.) was attached to side of the head of a subject and the LCP-based device was attached to opposite side. In both devices, alignment magnets were removed for safety. Magnetic resonance imaging (MRI) was performed on a widely used 3.0 T and an ultra-high 7.0 T MRI machine. 3.0 and 7.0 T MR images were acquired using T1- and T2(*)-weighted gradient echo sequences, respectively. RESULTS In the 3.0 T images, the metal-based device on the left side generated the significant amount of artifacts. The MR images in the proximity of the metal package were obscured by the artifacts in both axial and sagittal views. On the other hand, the MR images near the LCP-based device were relatively free from the artifacts and clearly showed the brain structures. 7.0 T MR images showed the more severe distortion in the both sides but the metal-based cochlear implant system caused a much larger obscure area than the LCP-based system. CONCLUSION The novel LCP-based cochlear implant provides a good MRI compatibility beyond present-day cochlear implants. Thus, MR images can be obtained from the subjects even with the implanted LCP-based neural prosthetic systems providing useful diagnostic information. Furthermore, it will be also useful for functional MRI studies of the auditory perception mechanism after cochlear implantations as well as for positron emission tomography-MRI hybrid imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic resonance imaging and cochlear implants: compatibility and safety aspects.

With cochlear implants, magnetic resonance imaging (MRI) has until recently been contraindicated due to excessive magnetic and electromagnetic interference. The aim of this study was to determine the MRI compatibility of the Med-E1 Combi 40/40+ cochlear implant, within a wide range of clinical MRI applications. In vitro experiments on a 1.5 T MR scanner were performed. Torque, force, demagnetiz...

متن کامل

An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

متن کامل

Cochlear Implantaion in Cases of Inner Ear Pathology

The inner ear pathology remains one of the most common problem in CI surgery [1,2]. Most of the complication after CI surgery main occurs specially in case of inner malformation and ossified cochlea [3,4]. The main purpose to determine the features of inner ear structure based on data of preoperatively imaging studies (high-resolution computer tomography and magnetic resonance imaging) and adeq...

متن کامل

Cochlear Implantation in Patient with Cochlear Nerve Deficiency: A Case Report.

Diagnostic imaging methods are very important for patients with bilateral sensourinoural hearing loss. Magnetic resonance imaging (MRI) is able to demonstrate the vestibulocochlear nerve and facial nerve in the internal acoustic canal. Also computed tomography can be helpful to determination of the deficiency of the cochlear nerve. Cochlear nerve anomalies are classified into three group accord...

متن کامل

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Background: In this work investigation of the normoxic PAGAT polymer gel dosimeter such as sensitivity, the R2-dose response with post time and the percentage depth dose (PDD) of PAGAT polymer gel dosimeter have been undertaken. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2 was determined to be 4.5% N,N'-methylenbis- ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2012