Evaluation of five new liquid stable applications on the Roche Cobas Integra.

نویسندگان

  • G Lippi
  • C Brentegani
  • C Mazzi
  • C Recchi
  • O Ruzzenente
  • G Guidi
چکیده

In the present study the analytical performances of five new liquid applications on the Roche Cobas Integra were evaluated: urea and high density lipoprotein (HDL) cholesterol in serum and glucose, creatinine and inorganic phosphorus in urine. The analytical evaluation consisted of imprecision, linearity and method comparison performed against either the actual Cobas Integra granulate applications or the corresponding methods on a Hitachi 704, according to the National Committee for Clinical Laboratory Standards protocols. Over 3700 results were obtained within 3 months. Average values of within-run and between-day coefficients of variation (CVs) were 1.15% and 1.48%, respectively, holding to a mean total CV of 2.17%. The linearity was excellent for all the five applications evaluated as the relative non-linearity was always within 1.53%, thus completely fulfilling the 2.5% upper limit. A strict correlation was observed by comparing results of 120 samples with either the corresponding granulate applications on Cobas Integra or the Hitachi reagents. Linear regression analysis of the results yielded correlation coefficients always above 0.987 and the slopes of the Passing & Bablok regression lines did not deviate by more than 7% from unity. No drift was observed over 4 hours of operations. In conclusion, the performance of these new Cobas Integra liquid applications, as demonstrated by the present study, proved them to be highly suitable for routine use in clinical laboratories.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of the Roche Total Mycophenolic Acid® assay on the Cobas Integra 400®, Cobas 6000® and comparison to LC-MS/MS in liver transplant patients.

BACKGROUND Mycophenolic acid (MPA) is an immunosuppressant for which therapeutic drug monitoring (TDM) is performed for optimal prophylaxis and avoidance of toxicity in transplant patients. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is ideally suited for TDM of MPA. There have been several method comparisons of the Roche Total MPA assay, but none have been performed with respect ...

متن کامل

Comparative evaluation of the My5-FU™ immunoassay and LC-MS/MS in monitoring the 5-fluorouracil plasma levels in cancer patients.

BACKGROUND Chemotherapies of solid tumors commonly include 5-fluorouracil (5-FU). With standard doses of 5-FU, substantial inter-patient variability has been observed in exposure levels and treatment response. Recently, improved outcomes in colorectal cancer patients due to pharmacokinetically guided 5-FU dosing were reported. We aimed at establishing a rapid and sensitive method for monitoring...

متن کامل

Analysis of lidocaine on the COBAS INTEGRA.

A new fluorescence polarization (FP) immunoassay was developed for the COBAS INTEGRA to quantitate lidocaine in serum and sodium heparin derived plasma. The COBAS INTEGRA, a random and continuous access clinical analyzer, performs the new lidocaine assay at a throughput of 300 tests per hour. Comparison studies with the Abbott TDx Lidocaine assay yielded a correlation coefficient of 0.99 and a ...

متن کامل

Performance evaluation of the new Roche cobas AmpliPrep/cobas TaqMan HCV test, version 2.0, for detection and quantification of hepatitis C virus RNA.

To evaluate the analytical performance and explore the clinical applicability of the new Roche cobas AmpliPrep/cobas TaqMan HCV test, v2.0 (CAP/CTM v2.0), a platform comparison was performed on panels and diagnostic samples with the Roche cobas AmpliPrep/cobas TaqMan HCV test (CAP/CTM v1.0), the Siemens Versant HCV RNA 3.0 branched DNA (bDNA) test, the Abbott m2000 RealTime HCV assay (Realtime ...

متن کامل

Performance of the Roche second generation hemoglobin A1c immunoassay in the presence of HB-S or HB-C traits.

Blood HbA1c determination is a powerful tool for the evaluation and management of patients with diabetes mellitus. Many HbA1c analytical methods demonstrate bias in samples from patients with hemoglobinopathies. This study evaluated the analytical performance of Roche Diagnostics' 1st and 2nd generation HbA1c assays in patients with or without hemoglobinopathies whose HbA1c levels were elevated...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies

دوره 35 11  شماره 

صفحات  -

تاریخ انتشار 1997