A revised schema for performing diagnostic x-ray shielding calculations.

نویسنده

  • E L McGuire
چکیده

This paper presents a method for performing diagnostic x-ray shielding calculations which is somewhat different than that given in NCRP Report No. 49. The method computes exposure at the location to be shielded from multiple sources of radiation in the room and accounts for differences in transmission characteristics of leakage and primary/scatter radiation. Also discussed in the paper is a method for determining shielding credit for existing common structural materials. Methods and results derived in the paper are then discussed and compared with NCRP Report No. 49.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation attenuation properties of shields containing micro and Nano WO3 in diagnostic X-ray energy range

Background: It has recently been shown that the particle size of materials used for radiation shielding can affect the magnitude of radiation attenuation. Over the past years, application of nano-structured materials in radiation shielding has attracted attention world-wide. The purpose of this study was to investigate the shielding properties of the lead-free shields containing micro and nano-...

متن کامل

A Novel Design for Production of Efficient Flexible Lead-Free Shields against X-ray Photons in Diagnostic Energy Range

Background: Lead-based radiation shields are widely used in radiology departments to protect both workers and patients from any unnecessary exposure to ionizing radiation. Recently there has been a great deal of concern expressed about the toxicity of lead. Human lead toxicity is well documented. In that light, production of environmentally-friendly lead-free radiation shields with less weight ...

متن کامل

Survey of the Use of X-ray Beam Collimator and Shielding Tools during Infant Chest Radiography

Background The use of shielding tools and X-ray beam collimator has extensively been advocated as effective methods to reduce radiation exposure to patients underwent radiological procedures. The aim of this study was to address the use of these protection measures during infant chest radiography. Material and Methods 348digital and/or analogue infant chest radiographs were reviewed that perfor...

متن کامل

Evaluation of the Prevalence and Utility of Gonad Shielding in Pediatrics Undergoing Pelvic X-Ray

Background: Gonad shielding has been recommended during pelvic x-rays since the 1950s. The popular method of gonad shielding is placement a lead shield in the midline of the pelvis. The aim of this study was to evaluate the prevalence and utility of gonad shielding in pediatrics undergoing pelvic x-rays.Materials and MethodsFollowing study approval, we retrospectively retrieved data from the di...

متن کامل

Shielding Calculations for the Hard X-ray Generated by Lcls Mec Laser System

LCLS Matter in Extreme Conditions (MEC) Instrument is an X-ray instrument that will be able to create and diagnose High Energy Density (HED) matter. The MEC laser system can generate hard X-ray due to the interaction of the laser and the plasma. This paper summarizes results of the shielding calculations performed to evaluate the radiation hazards induced by this hard X-ray source with Monte Ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Health physics

دوره 50 1  شماره 

صفحات  -

تاریخ انتشار 1986