Matched Filter EPI Increases BOLD-Sensitivity in Human Functional MRI

نویسندگان

  • L. Kasper
  • M. Häberlin
  • C. Barmet
  • B. J. Wilm
  • C. C. Ruff
  • K. E. Stephan
  • K. P. Prüssmann
چکیده

INTRODUCTION Post processing of MR images is omnipresent: for fMRI in particular, smoothing of the raw images is frequently applied to gain SNR on the spatial scale of the BOLD response (‘matched filter’). This shaping of the point spread function (PSF) acts complementary to sampling itself, where the choice of a k-space trajectory imposes an intrinsic filter onto the data. We combine both approaches to pursue SNR optimization through the choice of an optimal acquisition strategy, incorporating the prior knowledge about the target smoothing kernel. Specifically, the implications for temporal SNR and fMRI t-maps in the case of Gaussian weighting are considered for a 2D gradient-velocity modulated EPI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the benefits of multi-echo EPI for fMRI at 7 T

Functional MRI studies on humans with BOLD contrast are increasingly performed at high static magnetic field in order to exploit the increased sensitivity. The downside of high-field fMRI using the gradient-echo echo-planar imaging (GE-EPI) method is that images are typically very strongly affected by image distortion and signal loss. It has been demonstrated at 1.5 T and 3 T that image artifac...

متن کامل

Enhancement of temporal resolution and BOLD sensitivity in real-time fMRI using multi-slab echo-volumar imaging

In this study, a new approach to high-speed fMRI using multi-slab echo-volumar imaging (EVI) is developed that minimizes geometrical image distortion and spatial blurring, and enables nonaliased sampling of physiological signal fluctuation to increase BOLD sensitivity compared to conventional echo-planar imaging (EPI). Real-time fMRI using whole brain 4-slab EVI with 286 ms temporal resolution ...

متن کامل

Evaluation of Sensory Pathways in Spinal Cord by Comparison of fMRI Methodologies

Introduction: Today, clinicians and neuroscientists need to have a comprehensive survey of neurological pathologies and injuries. For the First-time, SEEP contrast and Spin-Echo pulse sequences was used for functional imaging of the Lumbar spinal cord. This method used by several research groups for Spinal cord mapping, but other researchers tried to improve BOLD fMRI to Spina...

متن کامل

Matched-filter acquisition for BOLD fMRI

We introduce matched-filter fMRI, which improves BOLD (blood oxygen level dependent) sensitivity by variable-density image acquisition tailored to subsequent image smoothing. Image smoothing is an established post-processing technique used in the vast majority of fMRI studies. Here we show that the signal-to-noise ratio of the resulting smoothed data can be substantially increased by acquisitio...

متن کامل

An evaluation of the use of passive shimming to improve frontal sensitivity in fMRI.

The presence of the head in an MRI scanner leads to inhomogeneities in the magnetic field. These cause the 'susceptibility artifacts' of image distortion and signal dropout. In this paper, we evaluate a technique called passive shimming, which has the potential to reduce field inhomogeneities and the resultant artifacts. A piece of a magnetically active material (pyrolytic graphite) is held on ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010