Dual-source CT in step-and-shoot mode: noninvasive coronary angiography with low radiation dose.

نویسندگان

  • Paul Stolzmann
  • Sebastian Leschka
  • Hans Scheffel
  • Tobias Krauss
  • Lotus Desbiolles
  • André Plass
  • Michele Genoni
  • Thomas G Flohr
  • Simon Wildermuth
  • Borut Marincek
  • Hatem Alkadhi
چکیده

PURPOSE To prospectively investigate computed tomographic (CT) image quality parameters by using different protocols and to calculate radiation dose estimates for noninvasive coronary angiography performed with dual-source CT in the step-and-shoot (SAS) mode. MATERIALS AND METHODS This study was local ethics board approved; written informed consent was obtained from all patients. In the preliminary portion of the study, 40 patients underwent CT coronary angiography in the SAS mode: at 100 kV (protocol A) in 22 patients with a body mass index (BMI) of less than 25 kg/m(2) and at 120 kV (protocol B) in 18 patients with a BMI of 25-30 kg/m(2). Both protocols involved use of an attenuation-based tube current and 1 mL of contrast material per kilogram of body weight. The final portion of the study involved 50 additional patients: 21 patients with a BMI of 25-30 kg/cm(2) assigned to protocol B and 29 patients with a BMI of less than 25 kg/cm(2) assigned to protocol C, which was performed with 100 kV, an attenuation-based tube current, and a reduced contrast material dose of 0.8 mL/kg. Image quality was independently assessed. Attenuation in the aorta and coronary arteries and image noise were measured. Radiation dose was estimated. RESULTS Mean image noise was similar with protocols A and B. Mean attenuation in the aorta and coronary arteries with protocol A (444 HU) was significantly (P < .001) higher than that with protocol B (358 HU). The reduced contrast material dose in protocol C yielded attenuation similar to that with protocol B. Diagnostic image quality was achieved with all protocols in 1237 (97.9%) of 1264 coronary segments. No significant differences in image quality between the 100- and 120-kV protocols were found. Mean heart rate had a significant effect on motion artifacts (area under receiver operating characteristic curve [AUC] = 0.818; 95% confidence interval [CI]: 0.723, 0.892; P < .001), whereas heart rate variability had a significant effect on stair-step artifacts (AUC = 0.79; 95% CI: 0.687, 0.865; P < .001). The mean estimated effective dose was 1.2 mSv +/- 0.2 for protocols A and C and 2.6 mSv +/- 0.5 for protocol B. CONCLUSION Dual-source SAS-mode CT coronary angiography yielded diagnostic image quality for 97.9% of coronary segments at a low radiation dose.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose

Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...

متن کامل

Radiation dose and physical image quality in 128‐section dual‐source computed tomographic coronary angiography: a phantom study

One-hundred-and-twenty-eight-section dual X-ray source computed tomography (CT) systems have been introduced into clinical practice and have been shown to increase temporal resolution. Higher temporal resolution allows low-dose spiral mode at a high pitch factor during CT coronary angiography. We evaluated radiation dose and physical image qualities in CT coronary angiography by applying high-p...

متن کامل

Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance.

OBJECTIVE To investigate the performance of low-dose, dual-source computed tomography (DSCT) coronary angiography in the step-and-shoot (SAS) mode for the diagnosis of significant coronary artery stenoses in comparison with conventional coronary angiography (CCA). DESIGN, SETTING AND PATIENTS Prospective, single-centre study conducted in a referral centre enrolling 120 patients (71 men, mean ...

متن کامل

Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose

Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...

متن کامل

[Coronary CT angiography using a prospective protocol. Comparison of image quality and radiation dose between dual source CT and single source CT].

OBJECTIVE To compare the image quality and radiation dose in a group of patients undergoing coronary CT angiography using a 128-slice dual source helical CT scanner with high pitch alto and prospective acquisition with those in a group of patients with similar clinical characteristics undergoing coronary CT angiography using a 128-slice single-source CT scanner with prospective sequential acqui...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiology

دوره 249 1  شماره 

صفحات  -

تاریخ انتشار 2008