In vivo structural characteristics of the femtosecond LASIK-induced opaque bubble layers with ultrahigh-resolution SD-OCT.
نویسندگان
چکیده
The authors report in vivo morphology of opaque bubble layers with ultrahigh-resolution anterior-segment optical coherence tomography (UHR-OCT) in 3 patients. Two patients were operated on with a 30-kHz IntraLase femtosecond laser (Abbott Medical Optics, Abbott Park, IL) and one patient was operated on with a 500-kHz VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany). UHR-OCT images from the patient operated on with the 500-kHz femtosecond laser revealed that the opaque bubble layer extended anterior to the flap dissection plane up to Bowman's membrane. The lamellar flap dissection was incomplete in this patient. The opaque bubble layer in the patients operated on with the 30-kHz femtosecond laser extended posterior to the flap dissection plane and these patients experienced complete lamellar dissections with uncomplicated flap lifts. UHR-OCT imaging can be used to demonstrate the structural characteristics of OBL. It has the potential to be used to predict incomplete lamellar flap dissections in patients with opaque bubble layers.
منابع مشابه
Digital analysis of flap parameter accuracy and objective assessment of opaque bubble layer in femtosecond laser-assisted LASIK: a novel technique
BACKGROUND The purpose of this study was to determine flap parameter accuracy, extent of the opaque bubble layer, and incidence of skip lines in femtosecond laser-assisted stromal in situ keratomileusis (LASIK) using the WaveLight(®) FS200 laser and optoelectronic clinical measurements. METHODS Images from 101 flaps were automatically recorded during consecutive routine LASIK procedures perfo...
متن کاملIn vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography.
An ultrahigh-speed spectral domain optical coherence tomography (SD-OCT) system is presented that achieves acquisition rates of 29,300 depth profiles/s. The sensitivity of SD-OCT and time domain OCT (TD-OCT) are experimentally compared, demonstrating a 21.7-dB improvement of SD-OCT over TD-OCT. In vivo images of the human retina are presented, demonstrating the ability to acquire high-quality s...
متن کاملIn vivo assessment of thickness and reflectivity in a rat outer retinal degeneration model with ultrahigh resolution optical coherence tomography.
PURPOSE To provide in vivo quantitative assessment of sodium iodate-induced retinal damage in a rat model of outer retinal degeneration using ultrahigh resolution optical coherence tomography (UHR-OCT). METHODS Outer retinal degeneration was induced in four female Long Evans rats via tail vein injection of sodium iodate (40 mg/kg). Changes in the thickness and optical reflectivity of individu...
متن کاملHistologic correlation of pig retina radial stratification with ultrahigh-resolution optical coherence tomography.
PURPOSE To compare ultrahigh-resolution optical coherence tomography (OCT) cross-sectional images of the pig retina with histology, to evaluate the potential of ultrahigh-resolution OCT for enhanced visualization of intra- and subretinal structures. METHODS Ultrahigh-resolution OCT images were acquired with 1.4- micro m axial x 3- micro m transverse resolution from in vitro posterior eyecup p...
متن کاملOpaque Bubble Layer Risk Factors in Femtosecond Laser-assisted LASIK.
PURPOSE To determine the characteristics and risk factors for occurrence of opaque bubble layer (OBL) during femtosecond laser-assisted flap creation for LASIK. METHODS One hundred ninety-eight eyes of 102 consecutive patients who underwent LASIK flap creation performed with the Alcon WaveLight FS200 laser (Alcon Laboratories, Inc., Fort Worth, TX) were retrospectively analyzed in a cohort st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye
دوره 41 Suppl شماره
صفحات -
تاریخ انتشار 2010