Preventing bath water scalds: a cost-effectiveness analysis of introducing bath thermostatic mixer valves in social housing.

نویسندگان

  • Ceri J Phillips
  • Ioan Humphreys
  • Denise Kendrick
  • Jane Stewart
  • Mike Hayes
  • Lesley Nish
  • David Stone
  • Carol Coupland
  • Elizabeth Towner
چکیده

AIMS To assess the cost-effectiveness of installing thermostatic mixer valves (TMVs) in reducing risks of bath water scalds and estimate the costs of avoiding bath water scalds. METHODS The evaluation was undertaken from the perspective of the UK public sector, and conducted in conjunction with a randomised control trial of TMVs installed in social housing in Glasgow. Installation costs were borne by the social housing organisation, while support materials were provided by the UK NHS. Effectiveness was represented by the number of families with at-risk bath water temperatures pre- and post-installation, and the number of bath scalds avoided as a result of installation. Differences in the number of families with at-risk temperatures between groups were derived from the RCT. Cost-effectiveness was assessed and a series of one-way sensitivity analyses were conducted. RESULTS Unit costs associated with installation were calculated to be £13.68, while costs associated with treating bath water scalds ranged from £25,226 to £71,902. The cost of an avoided bath water scald ranged from net savings to public purse of £1887 to £75,520 and at baseline produced a net saving of £3,229,008; that is, £1.41 saved for every £1 spent. CONCLUSION It is very likely that installing TMVs as standard in social housing in new buildings and major refurbishments accompanied by educational information represents value for money.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomised controlled trial of thermostatic mixer valves in reducing bath hot tap water temperature in families with young children in social housing.

OBJECTIVES To assess the effectiveness of thermostatic mixing valves (TMVs) in reducing bath hot tap water temperature, assess acceptability of TMVs to families and impact on bath time safety practices. DESIGN Pragmatic parallel arm randomised controlled trial. SETTING A social housing organisation in Glasgow, Scotland, UK. PARTICIPANTS 124 families with at least one child under 5 years. ...

متن کامل

Randomised controlled trial of thermostatic mixer valves in reducing bath hot tap water temperature in families with young children in social housing: A protocol

BACKGROUND Each year in the UK 2000 children attend emergency departments and 500 are admitted to hospital following a bath water scald. The long term effects can include disability, disfigurement or psychological harm and repeated skin grafts may be required as the child grows. The costs of treating a severe scald are estimated at 250,000 GBP. Children living in the most deprived wards are at ...

متن کامل

Patterns of scald injuries.

OBJECTIVES To describe common patterns of bath water scald injuries in children, to examine differences between accidental and non-accidental bath water scalds in children, and to examine potential for prevention. DESIGN A two year six month retrospective analysis of admissions to a specialist burns unit. SETTING The Burns Unit, St Lawrence Hospital, Chepstow serving children from south and...

متن کامل

Thirty-five years of paediatric scalds: are lessons being learned?

All paediatric scalds admitted in 1991 to the Welsh Centre for Burns and Plastic Surgery have been analysed retrospectively and the results compared with similar studies from this centre reported in 1956 and 1984. This data was compared with similar reports from 6 other world-wide centres. Despite a modest population increase in Wales, the number of admissions has increased almost 50% in 35 yea...

متن کامل

Influence of Tube Arrangement on the Thermal Performance of Indirect Water Bath Heaters

Natural convection heat transfer from a tube bundle in the indirect water bath heaters is investigated. A computer-code is used for the solution of the governing equations of mass, momentum and energy transfer based on the SIMPLE-C algorithm. Simulations are carried out for the gas pressure station heater of Kermanshah city with various tube bundle arrangements. In order to validate the numeric...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Injury prevention : journal of the International Society for Child and Adolescent Injury Prevention

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2011