A new technique for treating posttraumatic aniridia with aphakia: first results of haptic fixation of a foldable intraocular lens on a foldable and custom-tailored iris prosthesis.

نویسندگان

  • Martin S Spitzer
  • Efdal Yoeruek
  • Martin A Leitritz
  • Peter Szurman
  • Karl U Bartz-Schmidt
چکیده

We describe a new surgical technique for treating traumatic aniridia with aphakia and its results in a small consecutive case series. We attached a 3-piece acrylic intraocular lens through the haptics to a customized silicone iris prosthesis. The combined implant was inserted through a 5-mm incision and fixated with a transscleral suture in the ciliary sulcus using a knotless technique (Z suture). In all patients, the combined implant stayed firmly fixed within the sulcus and showed a stable and centered position without any tilt or torque during follow-up. Thus, managing posttraumatic aniridia with aphakia by means of haptic fixation of a foldable intraocular lens on a custom-tailored iris prosthesis is a promising approach for visual rehabilitation and cosmetic improvement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined transscleral fixation of an artificial iris prosthesis with an intraocular lens.

Post-traumatic aniridia combined with aphakia may be seen after globe injury. Aside from esthetic aspects, partial or total loss of the iris tissue may also be related to various degrees of glare and photophobia. Such patients suffer from severe visual impairment secondary to aphakia. Herein we describe a novel surgical technique for the management of an aphakic eye with traumatic aniridia for ...

متن کامل

Traumatic Partial Aniridia and Cataract after Iris-Fixated Foldable Phakic Intraocular Lens Implantation

We present the first case of partial aniridia, traumatic cataract, and peripapillary subretinal hemorrhage after blunt trauma to an eye containing a foldable iris-fixated phakic intraocular lens (pIOL). Although the patient experienced visual loss because of considerable corneal astigmatism and a traumatic cataract, vision was recovered by a 2-stage primary corneal repair and cataract surgery w...

متن کامل

Retropupilar positioning of foldable iris-claw intraocular lens for correction of aphakia with no capsular support

SUMMARY Iris-claw intraocular lens (ICIOL) for aphakia needs a large 5.4 mm corneal incision for its implantation. The technique needs corneal suture, associated with some postoperative astigmatism. Foldable ICIOL is used in phakic patients undergoing refractive surgery and has the advantage of a sutureless small corneal incision. We report a case of a high myopic patient with dislocated intrao...

متن کامل

Suture Fixation Technique for a Single-piece Foldable Closed-loop Intraocular Lens

PURPOSE We describe a suture fixation technique for a single-piece foldable acrylic closed-loop intraocular lens (IOL) (C-flex, Rayner). METHODS In our experimental model analyzing the stability of acrylic haptics, we confirmed that the IOL could be in counterpoise without tilt using only a two-point fixation. This new surgical technique was performed in seven patients. RESULTS The unique h...

متن کامل

Surgical technique for transscleral fixation of a foldable posterior chamber intraocular lens.

The safety and efficacy of a modified technique for transscleral fixation of a foldable posterior chamber intraocular lens (IOL) for intracapsular aphakia (secondary IOL) or after complicated phacoemulsification was evaluated. All eyes had inadequate or no posterior capsular support. Follow-up was between 4 and 26 months (mean, 12 months). Uncorrected visual acuity improved (> 2 lines) in all p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 130 6  شماره 

صفحات  -

تاریخ انتشار 2012