Fluorophotometry as a diagnostic tool for the evaluation of dry eye disease

نویسندگان

  • Magid M Fahim
  • Shamim Haji
  • Chakravarthy V Koonapareddy
  • Vincent C Fan
  • Penny A Asbell
چکیده

BACKGROUND Dry eye disease is a common debilitating ocular disease. Current diagnostic tests used in dry eye disease are often neither sensitive nor reproducible, making it difficult to accurately diagnose and determine end points for clinical trials, or evaluate the usefulness of different medications in the treatment of dry eye disease. The recently developed fluorophotometer can objectively detect changes in the corneal epithelium by quantitatively measuring its barrier function or permeability. The purpose of the study is to investigate the use of corneal fluorescein penetration measured by the fluorophotometer as a diagnostic tool in the evaluation of dry eye patients. METHODS Dry eye patients (16 eyes), who presented with a chief complaint of ocular irritation corresponding with dry eye, low Schirmer's one test (<10 mm after 5 minutes) and corneal fluorescein staining score of more than two, were included in the study. Normal subjects (16 eyes), who came for refraction error evaluation, served as controls. Institutional Review Board (IRB) approved consent was obtained before enrolling the subjects in the study and all questions were answered while explaining the risks, benefits and alternatives. All Fluorophotometry of the central corneal epithelium was done utilizing the Fluorotron Master. Each eye had a baseline fluorescein scan performed, after which 50 l of 1% sodium fluorescein dye was instilled. Three minutes later, the fluorescein was washed with 50 ml of normal saline. Fluorescein scans were then started immediately after washing and were recorded at 10, 20, 40, and 60 minutes thereafter. The corneal peak values of fluorescein concentration were recorded within the central cornea in both dry eyes and in controls. RESULTS Ten minutes after fluorescein installation, patients with dry eye disease averaged a five-fold increase in corneal tissue fluorescein concentration (mean = 375.26 +/- 202.67 ng/ml) compared with that of normal subjects (mean = 128.19 +/- 85.84 ng/ml). Sixty minutes after dye installation, patients with dry eye disease still revealed higher corneal tissue fluorescein concentration (mean = 112.87 +/- 52.83 ng/ml) compared with that of controls (mean = 40.64 +/- 7.96 ng/ml), averaging a three-fold increase. CONCLUSION Patients with dry eye disease demonstrated an increased corneal permeability and a slower rate of elimination to topically administered fluorescein when measured by the fluorophotometer. This suggests that fluorophotometry may serve as a valuable quantitative and objective tool for the diagnosis of dry eye disease, and in following patients' response to new treatment modalities. Fluorophotometry may serve as an objective non-invasive tool for end-point analysis in clinical trials of new treatments for dry eye disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corneal permeability changes in dry eye disease: an observational study

BACKGROUND Diagnostic tests for dry eye disease (DED), including ocular surface disease index (OSDI), tear breakup time (TBUT), corneal fluorescein staining, and lissamine staining, have great deal of variability. We investigated whether fluorophotometry correlated with previously established DED diagnostic tests and whether it could serve as a novel objective metric to evaluate DED. METHODS ...

متن کامل

Pilot, prospective, randomized, double-masked, placebo-controlled clinical trial of an omega-3 supplement for dry eye.

PURPOSE To investigate the potential effect of dietary supplementation with omega-3 fatty acid on lipid composition of meibum, aqueous tear evaporation, and tear volume in patients with dry eye. METHODS In a pilot, prospective, randomized, double-masked study, patients with dry eye received a daily dose of fish oil, containing 450 mg of eicosapentaenoic acid, 300 mg of docosahexaenoic acid, a...

متن کامل

Assessment of tear film dynamics: quantification approach.

The dynamics of the tear film are reviewed with specific reference to the biophysical aspects: distribution, turnover and elimination through evaporation, drainage, and absorption. The review concentrates on quantitative assessments and is confined to aspects of the dynamics that can be fully and directly measured. The techniques of fluorophotometry, fluorescein clearance, lacrimal scintigraphy...

متن کامل

[Reduction of corneal permeability in patients treated with HP-guar: a fluorophotometric study].

INTRODUCTION The incidence of dry eye disease, which mainly affects the corneal epithelium, is rising. The main treatment is still the use of artificial tears capable of improving the humidification and lubrication of the corneal epithelium, and avoiding its progressive functional failure. HP-Guar is a new compound used for this purpose. METHODS We performed a prospective, masked and paired s...

متن کامل

SCIENTIFIC CORRESPONDENCE A new technique for tear film fluorophotometry

Aim: To develop a reliable and objective non-touch technique for determination of tear volume and tear secretion by means of tear film fluorophotometry. Methods: 10 defined concentrations of sodium fluorescein were given in an artificial chamber and measured by the Fluorotron Master (Coherent Radiation Inc). A calibration line was established and the calibration equation was programmed into the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Ophthalmology

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2006