An immunochemical mass assay for the direct measurement of creatine kinase MB2.

نویسندگان

  • J P Laurino
  • E Fischberg-Bender
  • S Galligan
  • J Chang
چکیده

The isoforms of CK-MB have recently received attention as potential biochemical markers for the early diagnosis of an acute myocardial infarction. A sensitive (analytical sensitivity = 0.2 ng/ml) immunochemical mass assay for the direct measurement of the CK-MB2 isoform has been developed by us. This assay utilizes a specific monoclonal capture antibody directed against the B-subunit of CK-MB and a specific monoclonal antibody conjugate directed against the CK-M + lysine subunit. Owing to the lack of a World Health Organization standard for CK-MB, the percent CK-MB2 values had to be normalized by determining both CK-MB and CK-MB2 in assays which differ only in the specificity of the anti-CK-M conjugate. Thus, a related CK-MB immunochemical mass assay utilizing the identical capture antibody and a specific monoclonal antibody conjugate directed against the CK-M subunit was also developed. Analytical sensitivities of the CK-MB and CK-MB2 assays were determined to be 0.5 ng/ml and 0.2 ng/ml, respectively. Both CK-MB and CK-MB2 levels were determined in 46 hospitalized non-AMI patients and 35 non-hospitalized normal patients. Of the 46 hospitalized non-AMI patients (mean age = 70), 26 percent had either CK-MB and/or CK-MB2 values below the level of sensitivity of the CK-MB or CK-MB2 isoform assays. For patients with CK-MB values between 0.5 ng/ml and 2.99 ng/ml, the percent CK-MB2 values ranged from 35 percent to 97 percent. For patients with CK-MB values between 3.0 ng/ml and 6.5 ng/ml, the percent CK-MB2 values ranged from 23 percent to 72 percent. Similar results were obtained for the non-hospitalized group. This assay appears to be useful in determining the clinical utility of CK-MB2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative sensitivities and specificities of the mass measurements of CK-MB2, CK-MB, and myoglobin for diagnosing acute myocardial infarction.

We evaluated the clinical utility of the mass measurement of the tissue isoform of creatine kinase MB isoenzyme (CK-MB2) in the diagnosis of an acute myocardial infarction (AMI) by determining its sensitivity, specificity, and predictive value relative to those of CK-MB mass and myoglobin. Samples were obtained at 0, 4, 8, and 16 h postpresentation from 100 patients (41% with AMI). The order of...

متن کامل

Early diagnosis of acute myocardial infarction based on assay for subforms of creatine kinase-MB.

Thrombolytic therapy for patients with acute myocardial infarction (AMI) has produced the need for an accurate early diagnostic marker. We previously developed and assessed an assay for the creatine kinase (CK)-MB subforms; assay time is 25 minutes. Plasma MB2 (tissue subform) activity, MB1 (plasma-modified subform) activity, and MB2/MB1 ratio in 56 healthy individuals were 0.61 +/- 0.33 units/...

متن کامل

Standardization of creatine kinase-MB (CK-MB) mass assays: the use of recombinant CK-MB as a reference material.

BACKGROUND The AACC assembled a committee to identify and validate a standard creatine kinase MB isoenzyme (CK-MB) material to improve the comparability of CK-MB mass assays. METHODS Three protocols were used. In protocol I, various CK-MB materials prepared in different matrices were screened as candidate standards. In protocol II, participating manufacturers calibrated their systems with con...

متن کامل

Diagnostic evaluation of creatine kinase-2 mass and creatine kinase-3 and -2 isoform ratios in early diagnosis of acute myocardial infarction.

The diagnostic efficacy of creatine kinase (CK) isoforms (CK-3 and CK-2) was compared with measurement of CK-2 mass concentrations for the early diagnosis of myocardial infarction (MI). Serial serum samples drawn from 76 patients with confirmed MI and 55 non-MI patients were used for determining CK-2 mass concentrations and the MM3/MM1 (CK-3 isoforms) and MB2/MB1 (CK-2 isoforms) ratios. We comp...

متن کامل

Creatine kinase MM and MB isoforms in patients receiving thrombolytic therapy and acute angiography. TAMI Study Group.

Creatine kinase isoforms markers, including MB2 concentration, MB2/MB1 and MM3/MM1 ratios, and MT index (based on the "tissue" M subunits), were measured in serial specimens from 207 patients receiving thrombolytic therapy followed by acute angiography. The slope of release showed a significant relation (P < 0.05) between MB2 concentrations and patency, graded as TIMI 0 through TIMI 3; with reg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of clinical and laboratory science

دوره 25 3  شماره 

صفحات  -

تاریخ انتشار 1995