Comparison between Different Intensity Normalization Methods in 123I-Ioflupane Imaging for the Automatic Detection of Parkinsonism
نویسندگان
چکیده
Intensity normalization is an important pre-processing step in the study and analysis of DaTSCAN SPECT imaging. As most automatic supervised image segmentation and classification methods base their assumptions regarding the intensity distributions on a standardized intensity range, intensity normalization takes on a very significant role. In this work, a comparison between different novel intensity normalization methods is presented. These proposed methodologies are based on Gaussian Mixture Model (GMM) image filtering and mean-squared error (MSE) optimization. The GMM-based image filtering method is achieved according to a probability threshold that removes the clusters whose likelihood are negligible in the non-specific regions. The MSE optimization method consists of a linear transformation that is obtained by minimizing the MSE in the non-specific region between the intensity normalized image and the template. The proposed intensity normalization methods are compared to: i) a standard approach based on the specific-to-non-specific binding ratio that is widely used, and ii) a linear approach based on the α-stable distribution. This comparison is performed on a DaTSCAN image database comprising analysis and classification stages for the development of a computer aided diagnosis (CAD) system for Parkinsonian syndrome (PS) detection. In addition, these proposed methods correct spatially varying artifacts that modulate the intensity of the images. Finally, using the leave-one-out cross-validation technique over these two approaches, the system achieves results up to a 92.91% of accuracy, 94.64% of sensitivity and 92.65 % of specificity, outperforming previous approaches based on a standard and a linear approach, which are used as a reference. The use of advanced intensity normalization techniques, such as the GMM-based image filtering and the MSE optimization improves the diagnosis of PS.
منابع مشابه
Correction: Comparison between Different Intensity Normalization Methods in 123I-Ioflupane Imaging for the Automatic Detection of Parkinsonism
Copyright: © 2015 Brahim et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
متن کاملParametrization of textural patterns in 123I-ioflupane imaging for the automatic detection of Parkinsonism.
PURPOSE A novel approach to a computer aided diagnosis system for the Parkinson's disease is proposed. This tool is intended as a supporting tool for physicians, based on fully automated methods that lead to the classification of (123)I-ioflupane SPECT images. METHODS (123)I-ioflupane images from three different databases are used to train the system. The images are intensity and spatially no...
متن کاملComputerize classification of Benign and malignant thyroid nodules by ultrasound imaging
Introduction: Early detection and treatment of thyroid nodules increase the cure rate and provide optimal treatment. Ultrasound is the chosen imaging technique for assessment of thyroid nodules. Confirmation of the diagnosis usually demands repeated fine needle aspiration biopsy (FNAB). So, current management, has morbidity and non zero mortality. The goal of the present study ...
متن کامل123I-ioflupane brain SPECT and 123I-MIBG cardiac planar scintigraphy combined use in uncertain parkinsonian disorders
We evaluated the clinical usefulness of the combined use of I-ioflupane brain single photon emission computed tomography (SPECT) and I-metaiodobenzylguanidine (MIBG) cardiac scintigraphy in discriminating uncertain parkinsonism with vascular lesions in striatal nuclei at magnetic resonance imaging (MRI). Forty-three consecutive patients with uncertain parkinsonism and vascular lesions at MRI in...
متن کاملImprovement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database
Objective(s): I-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the util...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2015