Measurement of specific immunoglobulin E: intermethod comparison and standardization.

نویسندگان

  • M Plebani
  • D Bernardi
  • D Basso
  • F Borghesan
  • D Faggian
چکیده

Recently introduced "second-generation" techniques for specific IgE measurement have produced some analytical improvement, offering better clinical sensitivity than previous techniques. The aims of our study were to compare the analytical and clinical performances of four second-generation techniques for allergen-specific IgE measurement in serum and to ascertain whether the new system for reporting quantitative results contributes to greater clinical agreement between findings using the techniques considered. Allergen-specific IgE was measured using the CAP System, CARLA, ENEA, and AlaSTAT, and the findings were compared. A significant disagreement was found between CAP and ENEA for all allergens and between CAP and CARLA for D1 and G5. However, the clinical discrepancies were reduced by selecting method-specific thresholds using ROC analysis. Second-generation techniques enable us to obtain better standardization of results; however, the identification of a specific threshold appears to be a prerequisite for the appropriate clinical interpretation of the test findings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of frozen sera for FT4 standardization: investigation by equilibrium dialysis combined with isotope dilution-mass spectrometry and immunoassay.

BACKGROUND Serum-free thyroxine (FT4) testing is recommended for diagnosis or monitoring of thyroid dysfunction, particularly in cases of hormone binding abnormalities. However, the poor intermethod agreement among commercial FT4 assays suggests a need for standardization with a hierarchically higher measurement procedure. To that purpose, we applied equilibrium dialysis (ED) in combination wit...

متن کامل

Proficiency survey-based evaluation of clinical total and allergen-specific IgE assay performance.

CONTEXT The diagnostic algorithm for human allergic disease involves confirmation of sensitization by detection of allergen-specific immunoglobulin E (IgE) antibody in individuals suspected of having allergic disease because of a history of allergic symptoms after known allergen exposure. Previous studies showed wide disparity among clinically reported allergen-specific IgE levels from differen...

متن کامل

Serum immunoglobulin E and immunoglobulin G reactivity to Agaricus bisporus proteins in mushroom cultivation workers

Background and Purpose: Although molds are regarded as the main fungal allergen sources, evidence indicates that spores of Basidiomycota including Agaricus bisporus (A. bisporus) can be also found at high concentrations in the environment and may cause as many respiratory allergies as molds. The aim of the present study was to evaluate specific immunoglobulin E (IgE) and immunoglobulin G (IgG) ...

متن کامل

Comparison of 7 Published LC-MS/MS Methods for the Simultaneous Measurement of Testosterone, Androstenedione, and Dehydroepiandrosterone in Serum.

BACKGROUND Recently, LC-MS/MS was stated to be the method of choice to measure sex steroids. Because information on the mutual agreement of LC-MS/MS methods is scarce, we compared 7 published LC-MS/MS methods for the simultaneous measurement of testosterone, androstenedione, and dehydroepiandrosterone (DHEA). METHODS We used 7 published LC-MS/MS methods to analyze in duplicate 55 random sampl...

متن کامل

Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 9  شماره 

صفحات  -

تاریخ انتشار 1998