Blood Volume Required for Detection of Low Levels and Ultralow Levels of Organisms Responsible for Neonatal Bacteremia by Use of Bactec Peds Plus/F, Plus Aerobic/F Medium, and the BD Bactec FX System: an In Vitro Study.

نویسندگان

  • Diana P Lancaster
  • David F Friedman
  • Kathleen Chiotos
  • Kaede V Sullivan
چکیده

We used an in vitro technique to investigate blood volumes required to detect bacteremia and fungemia with low concentrations of an organism. At 1 to 10 CFU/ml, Escherichia coli, Staphylococcus epidermidis, Staphylococcus aureus, Listeria monocytogenes, Candida albicans, and Candida parapsilosis isolates were detected in volumes as low as 0.5 ml. Detection of Streptococcus agalactiae and detection of bacteremia at <1 CFU/ml were unreliable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of a BACTEC nonradiometric medium for pediatric blood cultures.

A BACTEC aerobic nonradiometric medium, PEDS Plus, designed for diagnosis of pediatric bacteremia was evaluated in three hospital centers. Equivalent blood volumes (up to 5 ml) were inoculated into and incubated in BACTEC NR-6A (6A) and PEDS Plus broths. Among 4,581 compliant sets, 289 clinically significant organisms, representing more than 20 bacterial and two Candida species, were isolated. ...

متن کامل

Laboratory experience with radiometric detection of bacteremia with three culture media.

In two long-term studies, the BACTEC radiometric system for detection of bacteremia was evaluated with three culture media each: (i) BACTEC media 6A (for aerobes) and 7B (for anaerobes) plus a thioglycolate medium and (ii) BACTEC media 6A, 7B, and 8A (hypertonic). In study 1, clinically significant isolates were identified in 1,873 (13.9%) of 13,432 blood cultures with all three media. The thio...

متن کامل

Comparison of BD Bactec Plus blood culture media to VersaTREK Redox blood culture media for detection of bacterial pathogens in simulated adult blood cultures containing therapeutic concentrations of antibiotics.

Antibiotic neutralization in blood culture media from two automated systems was evaluated by measuring the recovery of organisms and times to detection in simulated cultures. Overall, BD Bactec Plus media (Bactec FX system) outperformed TREK 80 ml Redox media (VersaTREK system), although results suggest a relative rather than an absolute increased rate of recovery for the Bactec media.

متن کامل

Controlled evaluation of Bactec Peds Plus/F and Bactec lytic/10 anaerobic/F media for isolation of Salmonella enterica serovars typhi and paratyphi A from blood.

We compared anaerobic lytic (AL) and pediatric aerobic resin-containing (Peds Plus/F) blood culture media for the isolation of Salmonella enterica serotype Typhi or Paratyphi A from children. The yields from AL and Peds Plus/F media were the same with equal volumes of blood, but recovery was faster from AL medium than Peds Plus/F medium (10.7 and 16.4 h, respectively) (P < 0.001).

متن کامل

Controlled clinical comparison of BACTEC plus anaerobic/F to standard anaerobic/F as the anaerobic companion bottle to plus aerobic/F medium for culturing blood from adults.

To determine the optimal anaerobic companion bottle to pair with BACTEC Plus Aerobic/F medium for recovery of pathogenic microorganisms from adult patients with bacteremia and fungemia, we compared Plus Anaerobic/F bottles with Standard Anaerobic/F bottles, each of which was filled with 4 to 6 ml of blood. The two bottles were paired with a Plus Aerobic/F bottle filled with 8 to 12 ml of blood....

متن کامل