The contegra® valved heterograft conduit for right ventricular outflow tract reconstruction: a reliable solution.
نویسندگان
چکیده
INTRODUCTION The Contegra® bioprosthetic valved conduit, a glutaraldehyde-preserved valve-containing bovine jugular vein graft (Contegra, Medtronic Inc., Minneapolis MN, USA) introduced for clinical trials in 1998, is used for reconstruction of the right ventricular outflow tract (RVOT), mainly in children. This study evaluates our surgical experience with the Contegra® graft, emphasizing the assessment of conduit durability at mid-term follow up. METHODS The intermediate results of RVOT reconstruction utilizing the Contegra conduit were retrospectively analyzed in a series of 34 consecutive patients (25 male, 9 female), with a mean age of 10.9 ± 11.2 years (range 0.2-46 years). Included were 14 patients with tetralogy of Fallot (TOF) with pulmonary atresia, 11 with reoperation of previously corrected TOF, 5 with truncus arteriosus, 2 with TOF with absent pulmonary valve, 1 reoperation of previously repaired double outlet right ventricle with pulmonary atresia, and 1 undergoing a Ross procedure. Contegra conduit sizes varied in diameter between 12 and 22 mm (mean 18.3 ± 3.2 mm). RESULTS There were no hospital deaths. There was one early conduit replacement as a result of recurrent thrombosis. Four patients developed early thrombus formation in a valve cusp with complete resolution following anticoagulation therapy. At mean follow up of 85 months (range 6-136 months) and median follow up of 95 months, one patient required Contegra graft explantation in another institution (indications unknown). Freedom from reoperation for Contegra grafts was 94% at 11.4 years. Mean transpulmonary pressure gradients remained low (9.6 ± 5.3 mmHg postoperative, 19.6 ± 10.6 mmHg at follow up). Although there was a clear trend towards worsening of conduit valve insufficiency, this was neither statistically significant nor considered clinically so. CONCLUSIONS In our experience of 34 consecutive operations, the Contegra® valved conduit for RVOT reconstruction seems to be a reliable alternative to homograft conduits, with promising mid-term freedom from structural deterioration and reoperation.
منابع مشابه
MRSA endocarditis of bovine Contegra valved conduit: a case report
BACKGROUND Different techniques are used for the right ventricular outflow tract reconstruction, including homo- or porcine xenografts, which have several limitations. Contegra, a bovine jugular vein graft, is an interesting alternative to overcome these limitations. It consists of a bovine jugular vein with a naturally integrated valve in it. Isolated pulmonary valve endocarditis is extremely ...
متن کاملContegra valved conduit in the paediatric population: an exciting prospect for right ventricle to pulmonary artery reconstruction; experience and outcomes at Aga Khan University.
OBJECTIVE The focus of this study is to share the experience and outcomes of Contegra graft implantation in the paediatric and adult population in Pakistan. METHODS Between May 2007 and July 2011, 16 patients, underwent implantation of a Contegra valved conduit. All operations were performed through a median sternotomy with cardiopulmonary bypass. Indications included: Pulmonary atresia with ...
متن کاملThe Contegra valved bovine conduit: a biomaterial for the surgical treatment of congenital heart defects.
Contegra, a bovine jugular vein graft, has been widely used as a preferable biomaterial in the surgical treatment of congenital heart defects, especially as a conduit for the right ventricular outflow tract reconstruction. This article aims to make a comprehensive review on the clinical outcomes of Contegra. Reports of Contegra published since 2002 were comprehensively retrieved, collected and ...
متن کاملImages in cardiovascular medicine: right ventricular outflow tract reconstruction with contegra bovine valved conduit.
A 11-year-old boy affected by truncus arteriosus (type 1) underwent a late complete repair in another institution. The right ventricular outflow tract reconstruction was performed with an 18-mm Contegra conduit (Medtronic Inc, Minneapolis, Minn) despite its contraindication in cases of pulmonary hypertension. An additional apical muscular ventricular septal defect was closed with a percutaneous...
متن کاملContegra conduit for reconstruction of the right ventricular outflow tract: a review of published early and mid-time results
OBJECTIVE The valved conduit Contegra (bovine jugular vein) has being implanted for more than 7 years in the right ventricular outflow tract and it is noted that the available reports have been mixed. The aim of this study is to review the reported evidence in the literature. METHODS Search of the relevant literature for the primary endpoints of operative mortality and morbidity and secondary...