Selective Thiol Detection in Authentic Biological Samples with the Use of Screen-printed Electrodes.

نویسندگان

  • Patricia T Lee
  • Richard G Compton
چکیده

A selective voltammetric determination of homocysteine and glutathione was applied to cell tissue culture media and human plasma via a single two-step method. The two-step method relies on the 1,4-Michael addition reaction between electro-oxidized catechol and the target thiol. Furthermore, the procedure relies on the differing reaction kinetics of the ortho-quinone with various thiol species giving different responses as a function of the scan rate. At faster scan rates homocysteine is only detected, while at slower scan rates the adduct signal reflects both homocysteine and glutathione. As a result, the quantification of both homocysteine and glutathione can be determined with a combination of both sets of data. The previous proof-of-concept (P. T. Lee, D. Lowinsohn, and R. G. Compton, Sensors, 2014, 14, 10395), is applied to the quantification of thiols in both tissue culture media and human plasma alone. Analytical parameters were determined for both homocysteine and glutathione in the respective media and the linear range. The sensitivities in tissue culture media are ca. 3 nA μM(-1) and ca. 1 nA μM(-1) and the limits of detections are ca. 2 μM and ca. 1 μM for homocysteine and glutathione, respectively. In human plasma, the sensitivities were determined to be 94 and 39 nA μM(-1), and the limit of detections are ca. 0.8 μM and ca. 0.8 μM for homocysteine and glutathione, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

The potentiality of the functionalized nitrogen and thiol-doped graphene quantum dots (GQDs-N-S) to stabilize the antibodies in the designing of human chorionic gonadotropin immunosensor

In this study, for the first time, a simple immunosensor for ultrasensitive recognition of Human Chorionic Gonadotropin (hCG) in serum samples was fabricated by exploiting a simple approach. In this method, a low-cost and sensitive immunosensor was fabricated based on QDs-N-S/Au nanoparticles (NPs) modified Screen-Printed Carbon Electrode (SPCE). It seems that, QDs-N-S/Au NPs/ antibody as a bio...

متن کامل

A New Sensor Based on Graphite Screen Printed Electrode Modified With Cu-Nanocomplex for Determination of Paracetamol

Paracetamol is a non-steroidal anti-inflammatory drug used as an antipyretic agent for the alternative to aspirin. Conversely, the overdoses of paracetamol can cause hepatic toxicity and kidney damage. Hence, the determination of paracetamol receives much more attention in biological samples and also in pharmaceutical formulations. Here, we report a rapid<span id="transmark" style="display: non...

متن کامل

Development of Novel Potentiometric Sensors for Determination of Lidocaine Hydrochloride in Pharmaceutical Preparations, Serum and Urine Samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations and biological fluids (urine and serum). It was based on potentiometric titration of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 31 7  شماره 

صفحات  -

تاریخ انتشار 2015