Reproduction of fretting wear at the stem-cement interface in total hip replacement.

نویسندگان

  • L Brown
  • H Zhang
  • L Blunt
  • S Barrans
چکیده

The stem-cement interface experiences fretting wear in vivo due to low-amplitude oscillatory micromotion under physiological loading, as a consequence it is considered to play an important part in the overall wear of cemented total hip replacement. Despite its potential significance, in-vitro simulation to reproduce fretting wear has seldom been attempted and even then with only limited success. In the present study, fretting wear was successfully reproduced at the stem-cement interface through an in-vitro wear simulation, which was performed in part with reference to ISO 7206-4: 2002. The wear locations compared well with the results of retrieval studies. There was no evidence of bone cement transfer films on the stem surface and no fatigue cracks in the cement mantle. The cement surface was severely damaged in those areas in contact with the fretting zones on the stem surface, with retention of cement debris in the micropores. Furthermore, it was suggested that these micropores contributed to initiation and propagation of fretting wear. This study gave scope for further comparative study of the influence of stem geometry, stem surface finish, and bone cement brand on generation of fretting wear.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Generation of Fretting Wear Debris at the Stem– Cement Interface in Total Hip Replacment

Fretting wear debris generated at the stem–cement interface has nowadays been considered to play an important role in the overall failure of cemented total hip replacement (THR). Those wear debris within a certain size range would transport along bone cement deficiencies to bone tissue, resulting in a significant bone resorption and subsequent aseptic loosening of the femoral component, which i...

متن کامل

Femoral stem wear in cemented total hip replacement.

The great success of cemented total hip replacement to treat patients with endstage osteoarthritis and osteonecrosis has been well documented. However, its long-term survivorship has been compromised by progressive development of aseptic loosening, and few hip prostheses could survive beyond 25 years. Aseptic loosening is mainly attributed to bone resorption which is activated by an in-vivo mac...

متن کامل

A combined experimental and finite element approach to analyse the fretting mechanism of the head–stem taper junction in total hip replacement

Fretting corrosion at the taper interface of modular hip implants has been implicated as a possible cause of implant failure. This study was set up to gain more insight in the taper mechanics that lead to fretting corrosion. The objectives of this study therefore were (1) to select experimental loading conditions to reproduce clinically relevant fretting corrosion features observed in retrieved...

متن کامل

A novel test method for evaluation of the abrasive wear behaviour of total hip stems at the interface between implant surface and bone cement.

After total hip replacement, some cemented titanium stems show above-average early loosening rates. Increased release of wear particles and resulting reaction of the peri-prosthetic tissue were considered responsible. The objective was to develop a test method for analysing the abrasive wear behaviour of cemented stems and for generating wear particles at the interface with the bone cement. By ...

متن کامل

The effect of different assembly loads on taper junction fretting wear in total hip replacements

Variability in the magnitude of the impaction force applied by surgeons to assemble a hip prosthetic head to a femoral stem could be a cause of increased wear in taper junctions. This study investigates the effect of varying the magnitude of the assembly force on fretting wear at the taper over a 10 year period using a 3D finite element model and wear algorithm. It is demonstrated that an incre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 221 8  شماره 

صفحات  -

تاریخ انتشار 2007