Utilization of a computerized intravenous insulin infusion program to control blood glucose in the intensive care unit.

نویسندگان

  • Rattan Juneja
  • Corbin Roudebush
  • Nilay Kumar
  • Angela Macy
  • Adam Golas
  • Donna Wall
  • Cheryl Wolverton
  • Deborah Nelson
  • Joni Carroll
  • Samuel J Flanders
چکیده

BACKGROUND This proof of concept study was designed to evaluate the safety and effectiveness of an intravenous insulin dosing calculator, the Clarian GlucoStabilizer program, and to determine the feasibility of its use as part of a glycemic control program. This paper discusses the impact of the GlucoStabilizer program on the glycemic control of intensive care patients with hyperglycemia. METHODS Patients admitted to the intensive care unit (ICU), requiring intravenous insulin, were treated using the GlucoStabilizer program. This program calculates an insulin drip rate based on the low and high blood glucose (BG) levels of the desired target range, the patient's current and previous BG levels, and an insulin sensitivity factor, with a goal of safely and expeditiously achieving and maintaining the patient's BG in the target range. RESULTS From October 2004 through March 2006, the GlucoStabilizer program has been used to treat 2,398 patients in the ICUs, with 177,279 BG measurements in its database. In these patients, 61.0% of BGs have been in the target range of 80-110 mg/dL, while 90.9% have been in the wider range of 60-150 mg/dL. The average BG was 106.5 mg/dL (SD 39.1 mg/dL), and the frequency of hypoglycemia (BG <50 mg/dL) was 0.4%. These results compare favorably with the level of glycemic control in the 3 months before implementation of the GlucoStabilizer program. CONCLUSIONS Use of the GlucoStabilizer program in the ICU resulted in improved glycemic control compared to the previous manually calculated glycemic control protocols.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nurse-led implementation of a safe and effective intravenous insulin protocol in a medical intensive care unit.

BACKGROUND Recent evidence has linked tight glucose control to worsened clinical outcomes among adults in intensive care units. OBJECTIVE To evaluate the effectiveness and safety of a nurse-led intravenous insulin protocol designed to achieve conservative blood glucose control in patients in a medical intensive care unit. METHODS A nurse-led intravenous insulin protocol was developed, targe...

متن کامل

Designing a glycemic control strategy to maintain glucose homeostasis and prevent hypoglycemia for subjects with type 1 diabetes

This paper presents using the fractional PImDn controller module which manipulates insulin infusion rate to maintain normoglycemia in subjects with type 1 diabetes. To prevent severe hypoglycemia, a conventional proportional controller is used to regulate glucagon infusion rate when the blood glucose levels fall below a threshold. Two sets of controller parameters are obtained and evaluated. Fo...

متن کامل

The effects of short term intravenous infusion of a soybean based lipid emulsion on some blood constituents in sheep: A preliminary study

To evaluate the effect of intravenous infusion of a soybean based lipid emulsion (Lipovenoes 10%) on some blood constituents in sheep, a replicated 2 × 2 Latin square design experiment was conducted in four clinically healthy ewes. Lipid emulsion (LE group) or normal saline (NS group) was infused intravenously at a rate of 0.025 mL kg-1 per min for 6 hr and the concentrations of bloo...

متن کامل

Changes in blood glucose concentrations over time when administering intravenous insulin in post cardiac surgery in adult intensive care patients

Introduction Patients in intensive care units (ICUs) are treated with intravenous (IV) insulin by infusions with the goal of maintaining blood glucose (BG) within a narrow target range. However, as BG is measured intermittently and how the time course of BG concentration changes after altering the insulin infusion rate is unknown. We used an intra-arterial Continuous Glucose Monitoring (CGM) sy...

متن کامل

Tight glycaemic control: a prospective observational study of a computerised decision-supported intensive insulin therapy protocol

INTRODUCTION A single centre has reported that implementation of an intensive insulin protocol, aiming for tight glycaemic control (blood glucose 4.4 to 6.1 mmol/l), resulted in significant reduction in mortality in longer stay medical and surgical critically ill patients. Our aim was to determine the degree to which tight glycaemic control can be maintained using an intensive insulin therapy p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Diabetes technology & therapeutics

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 2007