Buttonhole cannulation and clinical outcomes in a home hemodialysis cohort and systematic review.

نویسندگان

  • Christopher A Muir
  • Sradha S Kotwal
  • Carmel M Hawley
  • Kevan Polkinghorne
  • Martin P Gallagher
  • Paul Snelling
  • Meg J Jardine
چکیده

BACKGROUND AND OBJECTIVES The relative merits of buttonhole (or blunt needle) versus rope ladder (or sharp needle) cannulation for hemodialysis vascular access are unclear. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Clinical outcomes by cannulation method were reviewed in 90 consecutive home hemodialysis patients. Initially, patients were trained in rope ladder cannulation. From 2004 on, all incident patients were started on buttonhole cannulation, and prevalent patients were converted to this cannulation method. Coprimary outcomes were arteriovenous fistula-attributable systemic infections and a composite of arteriovenous fistula loss or requirement for surgical intervention. Secondary outcomes were total arteriovenous fistula-related infections and staff time requirements. Additionally, a systematic review evaluating infections by cannulation method was performed. RESULTS Seventeen systemic arteriovenous fistula-attributable infections were documented in 90 patients who were followed for 3765 arteriovenous fistula-months. Compared with rope ladder, buttonhole was not associated with a significantly higher rate of systemic arteriovenous fistula-attributable infections (incidence rate ratio, 2.71; 95% confidence interval, 0.66 to 11.09; P=0.17). However, use of buttonhole was associated with a significantly higher rate of total arteriovenous fistula infections (incidence rate ratio, 3.85; 95% confidence interval, 1.66 to 12.77; P=0.03). Initial and ongoing staff time requirements were significantly higher with buttonhole cannulation. Arteriovenous fistula loss or requirement for surgical intervention was not different between cannulation methods. A systematic review found increased arteriovenous fistula-related infections with buttonhole compared with rope ladder in four randomized trials (relative risk, 3.34; 95% confidence interval, 0.91 to 12.20), seven observational studies comparing before with after changes (relative risk, 3.15; 95% confidence interval, 1.90 to 5.21), and three observational studies comparing units with different cannulation methods (relative risk, 3.27; 95% confidence interval, 1.44 to 7.43). CONCLUSION Buttonhole cannulation was associated with higher rates of infectious events, increased staff support requirements, and no reduction in surgical arteriovenous fistula interventions compared with rope ladder in home hemodialysis patients. A systematic review of the published literature found that buttonhole is associated with higher risk of arteriovenous fistula-related infections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Buttonhole versus rope-ladder cannulation of arteriovenous fistulas for hemodialysis: a systematic review.

BACKGROUND The buttonhole technique is an alternative method of cannulating the arteriovenous fistula (AVF) in hemodialysis (HD), frequently used for home HD patients. However, the balance of risks and benefits of the buttonhole compared with the rope-ladder technique is uncertain. STUDY DESIGN A systematic review of randomized trials and observational studies (case reports, case series, stud...

متن کامل

A simple method to create buttonhole cannulation tracks in a busy hemodialysis unit.

The preference for fistulae as the hemodialysis access of choice has led to a significant number of accesses that are less than ideal for cannulation. Buttonhole cannulation is ideal for such accesses, but the technique for creation provides major challenges. In 12 patients, buttonhole tunnel tracks were created by leaving the polyurethane catheter of a Clampcath hemodialysis needle indwelling ...

متن کامل

Arterio-venous fistula buttonhole cannulation technique: a retrospective analysis of infectious complications

BACKGROUND There are two main methods of accessing arterio-venous fistulas (AVFs); the 'buttonhole' and the 'rope-ladder' cannulation technique. Several small studies have hypothesized that the buttonhole technique is associated with increased rates of fistula-associated infection. This study addresses this hypothesis. METHODS A retrospective review of all patients attending a large outpatien...

متن کامل

Should buttonhole cannulation be discontinued?

The arteriovenous fistula remains the preferred type of vascular access because of its higher patency and lower infection rates (1). Cannulation of the fistula remains a challenge for patients, caregivers, and nurses, often resulting in increased pain, stress, and vessel injury. The use of rotating puncture sites along the entire length of the fistula, or rope-ladder cannulation (RLC), was inte...

متن کامل

The salvage of aneurysmal fistulae utilizing a modified buttonhole cannulation technique and multiple cannulators.

We describe the St Michael's Hospital (SMH) modified buttonhole (BH) cannulation technique as a method that offers a solution for fistulae with aneurysmal dilatation due to repetitive cannulation in a restricted area. This is a prospective cohort study of 14 chronic hemodialysis (HD) patients with problematic fistulae (marked aneurysmal formation and thinning of the overlying skin, bleeding dur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical journal of the American Society of Nephrology : CJASN

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2014