Mechanical flow obstruction after heart transplantation diagnosed by TEE.

نویسندگان

  • J L Canivet
  • J O Defraigne
  • J C Demoulin
  • R Limet
چکیده

We report a case of mechanical flow obstruction after heart transplantation caused by a prominent left atrium suture with a "pursestring" effect. The diagnosis was achieved by transesophageal echocardiography. The mean transstenotic gradient was measured at 13 mm Hg. Because of the profound hemodynamic and multisystemic failure, no surgical correction was attempted. The postmortem examination confirmed the stenosis at the level of the left atrium.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systolic anterior motion of the anterior mitral leaflet after heart transplantation.

TRANSESOPHAGEAL echocardiography (TEE) is a new tool for the perioperative treatment of cardiac surgery patients. We report a clinical case to illustrate the usefulness of TEE for evaluating morphologic and fiinctional features of a cardiac graft. Mitral regurgitation (MR) secondary to left ventricular outflow tract obstruction with systolic anterior motion (SAM) of the anterior mitral leaflet ...

متن کامل

Transesophageal echocardiographic imaging of multiple complications following mitral valve replacement

UNLABELLED We present a case of mitral valve (MV) replacement that resulted in multiple complications, as diagnosed by transesophageal echocardiography (TEE), including left ventricular outflow tract obstruction, aortic dissection and left ventricular rupture. We also describe that identification of bleeding originating from the posterior aspect of the heart by the surgical team should trigger ...

متن کامل

Differentiation of thrombus from pannus as the cause of acquired mechanical prosthetic heart valve obstruction by non-invasive imaging: a review of the literature.

AIMS For acquired mechanical prosthetic heart valve (PHV) obstruction and suspicion on thrombosis, recently updated European Society of Cardiology guidelines advocate the confirmation of thrombus by transthoracic echocardiography, transesophageal echocardiography (TEE), and fluoroscopy. However, no evidence-based diagnostic algorithm is available for correct thrombus detection, although this is...

متن کامل

Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis

Prosthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission tomography including low-dose CT (FDG-PET) and three-dimensional transoesophageal echocardiography (3D-TEE) may have a...

متن کامل

Fatal course of perivalvular extension of infective endocarditis in a patient after aortic valve replacement treated with immunosuppressive drugs.

882 prosthetic mean gradient (83 mm Hg), indicat‐ ing valve obstruction. Transesophageal echocar‐ diography (TEE) showed mobile structures at‐ tached to the prosthesis, typical for bacterial veg‐ etations (Figure 1A) and inflammatory infiltration (22 × 8 mm) at the level of the non–coronary si‐ nus of Valsalva, involving the aortic and mitral curtain (Figure 1B). An evident perivalvular ab‐ sce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Annals of thoracic surgery

دوره 58 3  شماره 

صفحات  -

تاریخ انتشار 1994