Interobserver agreement for the assessment of handicap in stroke patients.

نویسنده

  • R F Bloch
چکیده

Interobserver agreement for the assessment of handicap in stroke patients was investigated in a group of 10 senior neurologists and 24 residents from two centers. One hundred patients were separately interviewed by two physicians in different combinations. The degree of handicap was recorded by each observer on the modified Rankin scale, which has six grades (0-5). The agreement rates were corrected for chance (kappa statistics). Both physicians agreed on the degree of handicap in 65 patients; they differed by one grade in 32 patients and by two grades in 3 patients. Kappa for all pairwise observations was 0.56; the value for weighted kappa (with quadratic disagreement weights) was 0.91. Our results confirm the value of the modified Rankin scale in the assessment of handicap in stroke patients; nevertheless, further improvements are possible.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interobserver Agreement for the Assessment of Handicap in Stroke Patients

Interobserver agreement for the assessment of handicap in stroke patients was investigated in a group of 10 senior neurologists and 24 residents from two centers. One hundred patients were separately interviewed by two physicians in different combinations. The degree of handicap was recorded by each observer on the modified Ran kin scale, which has six grades (0-5). The agreement rates were cor...

متن کامل

Assessment of interobserver variability in a Dutch multicenter study on acute ischemic stroke.

Quantitative assessment of patient data is a pertinent part of controlled clinical studies. When several centers are involved, the degree of agreement between different observers becomes important. Therefore, in addition to developing a multicenter study on acute ischemic stroke, we have estimated the interobserver agreement expressed in terms of kappa statistics. Twelve patients suffering from...

متن کامل

Interobserver Variability of Radiographic Assessment using a Mobile Messaging Application as a Teleconsultation Tool

Background: To examine whether interobserver reliability, decision-making, and confidence in decision-making in thetreatment of distal radius fractures changes if radiographs are viewed on a messenger application on a mobile phonecompared to a standard DICOM viewer.Methods: Radiographs of distal radius fractures were presented to surgeons on either a smart phone using a mobilemessenger applicat...

متن کامل

Qualitative Evaluation of Digital Hand X-rays is Not a Reliable Method to Assess Bone Mineral Density

Object: The gold standard for evaluating bone mineral density is dual energy x-ray absorptiometry (DEXA).  Prior studies have shown poor reliability using analog wrist X-rays in diagnosing osteoporosis. Our goal was to investigate if there was improved diagnostic value to visual assessment of digital hand X-rays in osteoporosis screening. We hypothesized that similar to analog counterparts, dig...

متن کامل

Reliability of the modified Rankin Scale.

Background and Purpose—A perceived weakness of the modified Rankin Scale is potential for interobserver variability. We undertook a systematic review of modified Rankin Scale reliability studies. Methods—Two researchers independently reviewed the literature. Crossdisciplinary electronic databases were interrogated using the following key words: Stroke*; Cerebrovasc*; Modified Rankin*; Rankin Sc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 20 6  شماره 

صفحات  -

تاریخ انتشار 1988