Investigation of pollution flashover on high voltage insulators using artificial neural network

نویسندگان

  • Muhsin Tunay Gençoglu
  • M. Cebeci
چکیده

0957-4174/$ see front matter Crown Copyright 2 doi:10.1016/j.eswa.2008.11.008 * Corresponding author. Tel.: +90 424 2370000/523 E-mail addresses: [email protected] (M.T. Ge (M. Cebeci). High voltage insulators form an essential part of the high voltage electric power transmission systems. Any failure in the satisfactory performance of high voltage insulators will result in considerable loss of capital, as there are numerous industries that depend upon the availability of an uninterrupted power supply. The importance of the research on insulator pollution has been increased considerably with the rise of the voltage of transmission lines. In order to determine the flashover behavior of polluted high voltage insulators and to identify to physical mechanisms that govern this phenomenon, the researchers have been brought to establish a modeling. Artificial neural networks (ANN) have been used by various researches for modeling and predictions in the field of energy engineering systems. In this study, model of VC = f (H,D,L,r,n,d) based on ANN which compute flashover voltage of the insulators were performed. This model consider height (H), diameter (D), total leakage length (L), surface conductivity (r) and number of shed (d) of an insulator and number of chain (n) on the insulator. Crown Copyright 2008 Published by Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flashover Voltage Estimation by Artificial Neural Network of Polluted Post Insulators Transmission Lines at High Altitude Area

In this work an attempt has been made to estimate the pollution flashover voltage under various meteorological factors using radial basis function (RBF) neural networks. Orthogonal least squares (OLS) learning method is used in order to improve the lines performance against the pollution flashover of the post insulators. The technique of RBF neural network is employed to model the relationship ...

متن کامل

Analysis of Leakage Current to Predict Insulator Flashover Using Artificial Neural Network

Problem statement: The phenomenon of flashover in polluted insulators has been continued by the study of the characteristics of contaminating layers deposited on the surface of insulators in high voltage laboratories. In the literature, Experimental investigations have been carried out on a real insulator or a flat plate model of insulators under high voltage application. This study proposed th...

متن کامل

Design of an artificial neural network for the estimation of the flashover voltage on insulators

This work attempts to apply an artificial neural network in order to estimate the critical flashover voltage on polluted insulators. The artificial eural network uses as input variables the following characteristics of the insulator: diameter, height, creepage distance, form factor and equivalent alt deposit density, and estimates the critical flashover voltage. The data used to train the netwo...

متن کامل

Computation of AC flashover voltage of polluted HV insulators using a dynamic arc model

Flashover of polluted insulators is still a serious threat to the safe operation of a power transmission system. Despite the extensive investigations carried out on the pollution performance of the insulators, the flashover characteristics are not well understood. Recent theoretical and experimental research on polluted insulators is yet to yield a perfect generalized mathematical model which c...

متن کامل

Designation of an Indicator for flashover prediction of porcelain and glass insulators based on experimental tests.

Flashover of polluted insulators in contaminated areas is one of the most important factors influencing the operation of transmission and distribution lines and finally line outages. Therefore, it is essential to prevent and detect flashover in the insulators. Hence, utilizing the insulator status monitoring systems and predicting their functions have absorbed a lot of attention over the recent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Expert Syst. Appl.

دوره 36  شماره 

صفحات  -

تاریخ انتشار 2009