A portable centrifugal analyser for liver function screening.

نویسندگان

  • Charles E Nwankire
  • Monika Czugala
  • Robert Burger
  • Kevin J Fraser
  • Tríona M O'Connell
  • Thomas Glennon
  • Blessing E Onwuliri
  • Isikaku E Nduaguibe
  • Dermot Diamond
  • Jens Ducrée
چکیده

Mortality rates of up to 50% have been reported after liver failure due to drug-induced hepatotoxicity and certain viral infections (Gao et al., 2008). These adverse conditions frequently affect HIV and tuberculosis patients on regular medication in resource-poor settings. Here, we report full integration of sample preparation with the read-out of a 5-parameter liver assay panel (LAP) on a portable, easy-to-use, fast and cost-efficient centrifugal microfluidic analysis system (CMAS). Our unique, dissolvable-film based centrifugo-pneumatic valving was employed to provide sample-to-answer fashion automation for plasma extraction (from finger-prick of blood), metering and aliquoting into separate reaction chambers for parallelized colorimetric quantification during rotation. The entire LAP completes in less than 20 min while using only a tenth the reagent volumes when compared with standard hospital laboratory tests. Accuracy of in-situ liver function screening was validated by 96 separate tests with an average coefficient of variance (CV) of 7.9% compared to benchtop and hospital lab tests. Unpaired two sample statistical t-tests were used to compare the means of CMAS and benchtop reader, on one hand; and CMAS and hospital tests on the other. The results demonstrate no statistical difference between the respective means with 94% and 92% certainty of equivalence, respectively. The portable platform thus saves significant time, labour and costs compared to established technologies, and therefore complies with typical restrictions on lab infrastructure, maintenance, operator skill and costs prevalent in many field clinics of the developing world. It has been successfully deployed to a centralised lab in Nigeria.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptation of methods for glutamate dehydrogenase and alcohol dehydrogenase activities to a centrifugal analyser: assessment of their clinical use in anoxic states of the liver.

Sensitive, precise, and rapid methods for the measurement of alcohol dehydrogenase (ADH) and glutamate dehydrogenase (GDH) were developed on the Cobas Bio centrifugal analyser. The optimal pH for ADH in caucasians was 9.8. Non-linearity of ADH enzyme activity was observed when samples were diluted in saline; linearity was restored when inactivated serum was used as diluent. ADH was shown to be ...

متن کامل

Tay-Sachs disease heterozygote detection: use of a centrifugal analyser for automation of hexosaminidase assays with two different artificial substrates.

An assay for measuring hexosaminidase A in serum and leucocytes is described in which a centrifugal analyser is used for automation of the enzyme assays after manual heat inactivation. The assay was used in a screening programme to identify heterozygotes for Tay-Sachs disease in Ashkenazi Jewish subjects in the UK. The first results from this programme indicate a carrier frequency of 1 in 27. A...

متن کامل

Validation of a portable nitric oxide analyzer for screening in primary ciliary dyskinesias

BACKGROUND Nasal nitric oxide (nNO) levels are very low in primary ciliary dyskinesia (PCD) and it is used as a screening test. METHODS We assessed the reliability and usability of a hand-held analyser in comparison to a stationary nitric oxide (NO) analyser in 50 participants (15 healthy, 13 PCD, 22 other respiratory diseases; age 6-79 years). Nasal NO was measured using a stationary NO anal...

متن کامل

Immunoturbidimetric assays for serum apolipoproteins A1 and B using Cobas Bio centrifugal analyser.

Immunoturbidimetric assays for measuring the apolipoproteins A1 and B using the Cobas Bio centrifugal analyser are described. The methods were specific, offered good sensitivity (less than 0.05 g/l) and intrabatch variability, with coefficients of variation between 2.4% and 3.5%, and were cost effective. Reference ranges were calculated for a group of civil servants, aged 35 to 55 years.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biosensors & bioelectronics

دوره 56  شماره 

صفحات  -

تاریخ انتشار 2014