Anatomical predictors for acute and mid-term success of cryoballoon ablation of atrial fibrillation using the 28 mm balloon.

نویسندگان

  • Sven Knecht
  • Michael Kühne
  • David Altmann
  • Peter Ammann
  • Beat Schaer
  • Stefan Osswald
  • Christian Sticherling
چکیده

INTRODUCTION Cryoballoon (CB) pulmonary vein isolation (CB-PVI) for the treatment of paroxysmal atrial fibrillation (AF) has been demonstrated to be safe and reliable. Preprocedural patient selection to address the high variability in pulmonary vein (PV) anatomy may improve the acute and chronic success of CB-PVI. The purpose of this study was to identify anatomical predictors for CB-PVI failure using the 28 mm balloon. METHODS AND RESULTS We included 47 patients with paroxysmal AF undergoing CB-PVI with the 28 mm CB. Anatomical global left atrial and PV selective parameters were quantified from 3-dimensional reconstructed preprocedural computed tomography or magnetic resonance imaging data. The mean follow-up was 26 ± 9 months (range: 12-32 months). Multivariate logistic regression analysis revealed that a continuous sharp left lateral ridge between the left PVs and the left lateral appendage (OR, 7.09; 95% CI, 1.17-43.47) and a sharp carina between the left superior and left inferior PV (OR, 5.99; 95% CI, 1.33-27.03) predict acute and mid-term failure. For the right inferior PVs, a non-perpendicular angle between the axis of the PV and the ostial plane (OR, 6.33; 95% CI, 1.20-33.33) and an early branching PV with change in the axis angle (OR, 7.41; 95% CI, 1.44-38.46) were predictors of acute and mid-term failure. CONCLUSION Anatomical variables preventing maximal heat transfer from the tissue to the CB could be identified as predictors for CB-PVI failure with the 28 mm balloon. These findings may be a step toward a more tailored ablation strategy based on individual anatomical variations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon.

BACKGROUND The use of second-generation cryoballoon for pulmonary vein isolation in patients with paroxysmal atrial fibrillation has demonstrated encouraging acute and mid-term results. Long-term outcome data are not yet available. METHODS AND RESULTS Fifty patients (18 women; mean age, 61±11 years; mean left atrial diameter, 43±5 mm) with paroxysmal (36 of 50 patients; 72%) or short-standing...

متن کامل

Impact of freezing time and balloon size on the thermodynamics and isolation efficacy during pulmonary vein isolation using the second generation cryoballoon.

BACKGROUND The differences in ablation characteristics of freezing time and balloon size using second generation cryoballoon are still unknown. METHODS AND RESULTS Twenty-six dogs underwent pulmonary vein (PV) isolation. Balloon and tissue temperatures (left atrial-PV junction, phrenic nerve, and internal esophagus) were monitored. The ablation duration was randomized to either 3 or 4 minutes...

متن کامل

Comparison of the first and second cryoballoon: high-volume single-center safety and efficacy analysis.

BACKGROUND Cryoballoon (CB) ablation results in >70% freedom from atrial fibrillation at 1 year. Single-center data of the first (CBG1) and second (CBG2) cryoballoon, recently introduced, were analyzed to compare safety and efficacy. METHODS AND RESULTS From March 2011 to December 2012, CB ablation with spiral mapping was performed consecutively in 484 patients with symptomatic atrial fibrill...

متن کامل

Cryoballoon ablation of paroxysmal atrial fibrillation: bigger is better and simpler is better.

Pulmonary vein isolation (PVI) is the mainstay of catheter ablation for atrial fibrillation. In an effort to overcome the shortcomings of drawing a continuous line around the pulmonary vein (PV) ostia by point-by-point focal radiofrequency catheter ablation, research in the interventional electrophysiology field currently focuses on developing new energy sources and catheter designs to achieve ...

متن کامل

Cryoballoon Ablation for Atrial Fibrillation

Focal point-by-point radiofrequency catheter ablation has shown considerable success in the treatment of paroxysmal atrial fibrillation. However, it is not without limitations. Recent clinical and preclinical studies have demonstrated that cryothermal ablation using a balloon catheter (Artic Front©, Medtronic CryoCath LP) provides an effective alternative strategy to treating atrial fibrillatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cardiovascular electrophysiology

دوره 24 2  شماره 

صفحات  -

تاریخ انتشار 2013