O10: Real-time magnetic resonance cine imaging with compressed sensing and iterative reconstruction for ventricular measures: comparison with gold-standard segmented steady-state free precession
نویسندگان
چکیده
O10: Real-time magnetic resonance cine imaging with compressed sensing and iterative reconstruction for ventricular measures: comparison with gold-standard segmented steady-state free precession Gabriel Camargo, Leticia R Sabioni, Thomas Doring, Ralph Strecker, Maria Eduarda Derenne, Vania M Naue, Tamara Rothstein, Michaela Schmidt, Michael O Zenge, Mariappan S Nadar, Ronaldo S Lima, Ilan Gottlieb
منابع مشابه
Real-time magnetic resonance cine imaging with sparse sampling and iterative reconstruction for ventricular measures: comparison with gold-standard segmented steady-state free precession
Background Segmented cine imaging with a steady-state free precession sequence (CINE-SSFP) is currently the gold standard technique for measuring ventricular volumes and mass. It requires multiple breath-holds to cover the entire ventricles, thus being prone to misalignment of consecutive slices, time consuming and dependent on breath-hold (BH) capability. Real-time cine avoids those limitation...
متن کاملFeasibility study of a novel acquisition technique of cardiac cine magnetic resonance imaging in patients with atrial fibrillatio
Background For patients with arrhythmia, conventional segmented steady-state free precession sequence (CINE-SSFP) methods may result in poor image quality. Real-time cine could avoid those limitations, however poor spatial and temporal resolutions of conventional sequences have prevented its routine application. Recently a newly developed compressed sensing (CS) cine shows the ability to provid...
متن کاملSegmented CMR acquisition with iterative SENSE reconstruction using L1-regularization in the evaluation of right ventricular systolic function
Background Cardiac MR (CMR) has emerged as the gold standard in assessing biventricular size and systolic function with segmented balanced steady-state free-precession (bSSFP) cine acquisitions. The application of a novel prototype iterative reconstruction technique to sparsely undersampled segmented bSSFP cine acquisitions may enable higher acceleration factors while shortening image acquisiti...
متن کاملHighly-Accelerated Real-Time Cine MRI using compressed sensing and parallel imaging
Introduction Breath-hold cine MRI with balanced steady-steady free precession (b-SSFP) may yield non diagnostic image quality in patients with impaired breath-hold capacity and/or arrhythmias. In such patients, it may be necessary to perform real-time cine MRI. Currently, dynamic parallel imaging methods, such as TSENSE [1] and TGRAPPA [2], can be used to achieve only moderate acceleration rate...
متن کاملFree-breathing real-time cardiac cine MR for evaluation of left-ventricular function: Comparison to standard multi-breath-hold cardiac cine MR in 50 patients
Background Electrocardiogram (ECG)-gated breath-hold cardiac cine magnetic resonance imaging (MRI) is generally accepted as the gold standard for left-ventricular (LV) volume assessment. However, it may fail in patients with arrhythmia, impaired breath-hold capacity, and poor ECG gating. Recently, sparse real-time (RT) cine using a prototype sequence with sparse sampling and iterative reconstru...